Product Manual

Page 5
IMPORTANT INFORMATION
Read all instructions before using this equipment. Save these instructions for future reference.
Remember:
1. Start up preparations:
Supply air line should be sized appropriately. See page 14. All hoses should be rated at
least 125 PSI and an isolation valve should be installed so that supply air can be turned off
and then disconnected from blast machine for servicing.
Supply air should be dry and clean from oil and other contaminants. (i.e. use air dryer,
coalescent filter, or moisture separator as needed.)
Blast machine must be grounded to avoid shock.
Electric extension cords should be three wire grounded, and rated for the amperage of the
blaster. Check nameplate for rated amps.
2. Operator’s responsibilities before starting:
Inspect fittings and hoses for damage and wear.
Check the seal on all doors. Only operate the blast cabinet with all doors securely closed
and dust collection system running.
Clean dust from dust collector and clean filter as needed.
3. Caution:
Unless otherwise specified, working pressure of blast machine and related components
must not exceed 110 PSI.
Keep blast nozzle controlled and aimed at the work.
4. Maintenance:
Keep your machine in good repair. Use ALLSOURCE parts and do not substitute or modify
ALLSOURCE supplied items.