Product Manual

Page 3
WARNING AND SAFETY INFORMATION
Do not operate cabinet or air flow with cabinet door
Open or with cabinet lens removed.
Do not use fluids or mix fluids with blast media.
This cabinet is designed for dry blasting only.
Do not exceed maximum operating pressure of 110 PSI.
WARNING!
Disconnecting hose while Unit is under pressure could cause serious injury or death. Use safety
lock pins and safety cables in all coupling connections to help prevent hose couplings from
accidental disconnection.
WARNING!
Failure to observe the following before performing any maintenance could cause serious injury or
death from the sudden release of compressed air:
- Disconnect power supply
- Lockout and tagout the compressed air supply
- Bleed the air supply line to the blast gun.
Immediate replacement of worn components is required. Failure to replace worn components could
expose the operator or bystanders to high speed media and compressed air could cause death or
serious injury.
Leaks around couplings and nozzle holders indicate worn or loose fitting parts. Nozzle holders and
couplings that do not fit tightly on hose and nozzles that do not fit tightly in nozzle holders could
disconnect while under pressure. Impact from nozzles, couplings, hoses, or abrasive, and parts
disconnected while under pressure could cause severe injury.
The threads on the nozzle holder must be inspected each time the nozzle is secured to the holder.
Check the threads for wear, and make sure nozzle screw securely grips the nozzle. The nozzle
washer must also be inspected for wear. Worn nozzle washers cause erosion. A loose-fitting nozzle
may eject from the holder under pressure and could cause severe injury.