Technical data
Table Of Contents
- FOREWORD
- TABLE OF CONTENTS
- CONGRATULATIONS
- WARRANTY
- ON-LINE WARRANTY REGISTRATION
- SAFETY NOTICE
- IMPORTANT INFORMATION
- PURPOSE OF THIS MANUAL
- SYSTEM DESCRIPTION
- UNPACKING AND INSPECTION
- COMPUTER SYSTEM REQUIREMENTS
- CONTROLS AND INDICATORS
- TECHNICAL DATA
- ABBREVIATIONS
- SITE SELECTION
- SYSTEM SETUP
- PLATE CARE & PREPARATION
- IMAGING PROCEDURES
- POWERING DOWN THE SYSTEM
- MAINTENANCE
- TROUBLESHOOTING
- ACCESSORIES

14
SYSTEM SETUP
Note: Authorized Imaging Software supplied by the dealer or other company, must be
installed on the computer in order to operate the ScanX.
ScanX Drivers and Utilities Installation
Before connecting the ScanX to your computer or attempting to use it for the first
time, run the Setup program on the ScanX Drivers and Utilities Disk included with
the ScanX. Normally, this program runs automatically when the CD is inserted
into the drive for the first time. If not, run the Setup program located in the root
directory of the CD (typically D:\Setup.exe).
The Setup program guides you through updating the library files on your com-
puter, which must be completed before the ScanX will operate properly. More
information can be found in the Installation Instructions and Notes file on the
ScanX Drivers and Utilities Disk included with the ScanX.
ScanX Connection Procedure
Refer to Figure 2 and perform the following procedure to connect the ScanX for
operation for the first time.
1. Select a location that meets the SITE SELECTION guidelines.
2. Set up the computer according to the manufacturer's recommendations.
Make sure that the computer meets all requirements listed on page 10.
3. Verify that an authorized Imaging Software is installed properly on the com-
puter.
4. Verify that the supplied ScanX Drivers and Utilities Disk which contains the
USB drivers was properly installed per instructions above.
Note: Always make sure to use the same USB port whenever re-connection of the USB cable
is necessary.
5. Connect the high speed USB cable between the USB Type B connector
located on the ScanX panel and the USB Type A connector located on the
computer.
Note: Connect the line cord to the ScanX prior to plugging the line cord into the Mains out-
let.
6. Connect the line cord between the Mains outlet and the IEC connector
located on the ScanX panel. The scanner is now in the Standby mode.
7. Turn ON the main power to the ScanX by placing the rocker switch on
the Built-In Control/Connector panel to the ON (I) position.
8. Switch the scanner from standby to ON by pressing the membrane READY
switch ( ) located on the Keypad Control Panel on the top of the scanner.
Verify that both the green and blue LED indicators above the READY and
ERASER switches, repectively, illuminate.
Note: The Found New Hardware Wizard may appear each time you plug the ScanX into a
different USB port on your computer.
9. With both the ScanX and computer turned on, Windows detects the ScanX
as a new USB Device and the Found New Hardware Wizard will appear.
Windows should automatically find the drivers installed from the ScanX
Drivers and Utilities Disk. After the wizard completes the first time, it will
appear and complete a second time and then third, and final time.