Specifications

AS-Interface slaves
3SF5 pushbuttons and indicator lights
AS-Interface enclosures and front panel modules
General data
6/121
Siemens IK PI · 2012
6
Overview
Distributed command devices of the 3SB3 series can be quickly
connected to the AS-Interface using AS-Interface enclosures.
Using suitable components you can make your own enclosures
with integrated AS-Interface or flexibly modify existing enclo-
sures.
Enclosures
Color of enclosure cover:
Gray, RAL 7035, or
Yellow, RAL 1004, for EMERGENCY-STOP.
Color of enclosure base:
Black, RAL 9005
Installation of AS-Interface slaves
The following
slave types are available for connecting the command points:
Slave in A/B technology with 4 inputs and 3 outputs
Slave with 4 inputs and 4 outputs
F Slave with two secure inputs for EMERGENCY-STOP
mushroom pushbutton
The following table shows the maximum number of equippable
slaves:
1)
For metal enclosures with 4 command points, only 1 x slave 4I/4O
or 4I/3O is possible.
Connection
For connecting a slave to contact blocks and lampholders and
the connection element, one set of links is needed for each.
The connection elements are mounted in the front-end cable
glands and are used for connection of the AS-Interface or for
bringing unused inputs or outputs out of the enclosure.
For connection to AS-Interface can be selected between:
Terminal for shaped AS-Interface cable.
The cable is contacted by the insulation piercing method and
routed past the enclosure on the outside (possible only with
plastic enclosure).
Cable gland for the shaped AS-Interface cable or round
cable. The cable is routed into the enclosure (preferable for
metal enclosure).
Connection using M12 plug.
If less than all inputs/outputs of the installed slaves in an enclo-
sure are used for connecting the command devices, free inputs
and outputs can be routed on request to the outside through an
M12 socket on the top or bottom side of the enclosure.
To supply inputs with power, the S+ connection of the must be
assigned to the socket, for outputs the OUT– connection must
be assigned.
Addressing is performed using the AS-Interface connections or
the integrated addressing socket. An external power supply is
not required.
Note
:
Dimensional drawings, manuals and further technical
information can be found on the Internet at:
www.siemens.com/industrial-controls/support
NSD0_01414
Enclosures for Number of slaves
for enclosures
without
EMERGENCY-STOP
Number of slaves
for enclosures
with
EMERGENCY-STOP
1 command point Not available 1 x F slave
2 command points 1 x slave 4I/4O
or 4I/3O
Not available
3 command points 1 x slave 4I/4O
or 4I/3O
1 x slave 4I/4O or 4I/3O
+ 1 x F slave
4 command points 2 x slave 4I/4O
or 4I/3O
1)
2 × slave 4I/4O or 4I/3O
+ 1 × F slave
1)
6 command points 2 x slave 4I/4O
or 4I/3O
2 x slave 4I/4O or 4I/3O
+ 1 x F slave
Kap_06_en.book Seite 121 Freitag, 2. September 2011 1:42 13