Specifications

AS-Interface slaves
SINAMICS G110D distributed frequency converters
General data
6/120
Siemens IK PI · 2012
6
Selection and ordering data (continued)
Note:
For further information on technical data, accessories and
ordering data see Catalog D 31 and Industry Mall at
www.siemens.com/industrymall
Order No.
Accessories
Manual on-site control with
key-operated switch
6SL3 255-0AA00-4HA0
Simple operation for local operation
and commissioning
RS232 interface cables 3RK1 922-2BP00
Connection cable for the commis-
sioning of the SINAMICS G110D
frequency converter with the
STARTER commissioning tool
USB interface cable 6SL3 555-0PA00-2AA0
Connection cable for the commis-
sioning of the SINAMICS G110D
frequency converter with the
STARTER commissioning tool
Braking resistors for
SINAMICS G110D frequency
converters
For the reduction of excess power
from the link
• Rated power 0.75 kW and 1.5 kW 6SL3 501-0BE08-6AA0
• Rated power 3 kW and 4 kW 6SL3 501-0BE12-1AA0
• Rated power 5.5 kW and 7.5 kW 6SL3 501-0BE14-1AA0
Intelligent Operator Panel IOP
Handheld
6SL3 255-0AA00-4HA0
For use with SIMATIC ET 200S FC
or SIMATIC ET 200pro FC
frequency converters
Included in scope of supply:
• Intelligent Operator Panel IOP
• Handheld enclosure
• Batteries (4 × AA)
• Charger (international)
• RS232 connection cable
(length 3 m, may only be used for
SINAMICS G120 and
SIMATIC ET 200S FC)
• USB cable (length 1 m)
Memory card
The parameterization of a converter
can be saved on the memory card.
For service purposes, e.g. after
replacement of a converter and
retrieval of data from the memory
card, the system is ready for use
again immediately.
• SINAMICS Micro Memory Card
(MMC)
6SL3 254-0AM00-0AA0
• SIMATIC
Memory Card (SD card)
6ES7 954-8LB00-0AA0
Card holder for memory card 6SL3 555-0PM00-0AA0
Use of the memory card requires a
card holder that can be plugged in
both under the blanking cover and
under the optional
manual on-site controller
Order No.
Accessories (continued)
Plug-in connector set for braking
resistor
6SL3 563-4RA00-0GA00
For the use or connection of other
braking resistors to the
SINAMICS G110D
UL plug-in connector set 6SL3 563-4UA00-0GA0
For power and motor for the use of
SINAMICS G110D in UL-compatible
applications
Memory card
The parameterization of a converter
can be saved on the memory card.
For service purposes, e.g. after
replacement of a converter and
retrieval of data from the memory
card, the system is ready for use
again immediately.
• SINAMICS Micro Memory Card
(MMC)
6SL3 254-0AM00-0AA0
• SIMATIC Memory Card (SD card) 6ES7 954-8LB00-0AA0
Card holder for memory card 6SL3 555-0PM00-0AA0
The use of the memory card
requires a card holder that can be
plugged in both under the blanking
cover and under the optional
manual on-site controller
Plug-in connector set for braking
resistor
6SL3 563-4RA00-0GA00
For the use or connection of other
braking resistors to the
SINAMICS G110D
UL plug-in connector set 6SL3 563-4UA00-0GA0
For power and motor for the use of
SINAMICS G110D in UL-compatible
applications
Plug protection bracket
To protect the plug against shearing
off due to mechanical effects
• For sizes FSA and FSB 6SL3 263-1HA20-0GA0
• For size FSC 6SL3 263-1HC20-0GA0
Adapters 6SL3 263-1GA20-0GA0
For installation of the
SINAMICS G110D instead of a
SIRIUS M200D motor starter
Kap_06_en.book Seite 120 Freitag, 2. September 2011 1:42 13
© Siemens AG 2011