Specifications
AS-Interface slaves
SINAMICS G110D distributed frequency converters
General data
6/118
Siemens IK PI · 2012
6
■
Benefits
• Wide performance range from 0.75 kW to 7.5 kW
• Rapid commissioning and maintenance thanks to expanded
diagnostics functions and communication capability with
AS-Interface in accordance with Specification 3.0
- Reduction of interfaces
- System-wide engineering
- Simple handling
• The design, installation and conversion of the system are
made much easier by the compact and space-saving design
with its very flat form and identical hole dimensions for all pow-
ers; the dimensions are also identical to those of the
SINAMICS G120D converter.
• Simple commissioning and maintenance thanks to identical,
standardized plug-in connections for the bus, power and
I/O connections (ISO 23570) over the entire performance
range of the SINAMICS G110D and SINAMICS G120 D fre-
quency converters.
• Use of the same plug for SIRIUS M200D motor starter
• Simple, consistent realization of complete, distributed system
concepts by the scalable use of the products:
- SIRIUS M200D (motor starters)
- SINAMICS G110D
(converters for simple conveyor applications)
- SINAMICS G120D
(converters for demanding conveyor applications)
• Very user friendly thanks to the use of the Intelligent Operator
Panel (IOP) for parameterization, diagnostics and control and
for the copying of drive parameters in the BOP
• Easy replacement thanks to plug-in connections and excellent
ease of maintenance thanks to the use of a memory card
• Simple connection, configuration, data storage and control of
the converter in complex systems by consistent integration
into TIA (Totally Integrated Automation)
• Thanks to the optional maintenance switch it is easy to discon-
nect the converter from the network for servicing without hav-
ing to provide for additional components or additional wiring
outlay during configuration.
• The optional manual on-site operation allows rapid spatially
restricted commissioning, manual pre-testing of the applica-
tion on site and validation running to be performed without ex-
pensive options
• Thanks to the option of the direct connection of up to five sen-
sors to the device, almost all drive-related information can be
managed directly; a local pre-processing of the signals re-
lieves the field bus whilst ensuring a rapid and reproducible
response time
• Integrated EMC filter Class A (according to EN 55011)
• Integrated brake actuation, supported braking voltages
400 V AC / 180 V DC and 230 V AC / 205 V DC
• Integrated motor protection thanks to thermal motor model
and evaluation of PTC, Thermo-Click or KTY 84 temperature
sensors
• Simple device replacement and time-saving copying of pa-
rameters to the memory card by the optional memory card
holder and the optional MMC memory card
• Engineering and commissioning with uniform engineering
tools such as SIZER (from V3.2), STARTER (from V4.1.3) and
Drive ES ensure rapid configuration and simple commission-
ing – with Drive ES Basic STARTER is integrated into STEP 7
providing the benefits of central data storage and consistent
communication
• Software parameters for simple adaptation to 50 Hz or 60 Hz
motors (IEC or NEMA motors)
• Increased robustness and longer service life due to painting
of the electronics assemblies
• Certified worldwide according to CE, UL, c-tick
Kap_06_en.book Seite 118 Freitag, 2. September 2011 1:42 13
© Siemens AG 2011