Specifications

AS-Interface slaves
SINAMICS G110D distributed frequency converters
General data
6/118
Siemens IK PI · 2012
6
Benefits
Wide performance range from 0.75 kW to 7.5 kW
Rapid commissioning and maintenance thanks to expanded
diagnostics functions and communication capability with
AS-Interface in accordance with Specification 3.0
- Reduction of interfaces
- System-wide engineering
- Simple handling
The design, installation and conversion of the system are
made much easier by the compact and space-saving design
with its very flat form and identical hole dimensions for all pow-
ers; the dimensions are also identical to those of the
SINAMICS G120D converter.
Simple commissioning and maintenance thanks to identical,
standardized plug-in connections for the bus, power and
I/O connections (ISO 23570) over the entire performance
range of the SINAMICS G110D and SINAMICS G120 D fre-
quency converters.
Use of the same plug for SIRIUS M200D motor starter
Simple, consistent realization of complete, distributed system
concepts by the scalable use of the products:
- SIRIUS M200D (motor starters)
- SINAMICS G110D
(converters for simple conveyor applications)
- SINAMICS G120D
(converters for demanding conveyor applications)
Very user friendly thanks to the use of the Intelligent Operator
Panel (IOP) for parameterization, diagnostics and control and
for the copying of drive parameters in the BOP
Easy replacement thanks to plug-in connections and excellent
ease of maintenance thanks to the use of a memory card
Simple connection, configuration, data storage and control of
the converter in complex systems by consistent integration
into TIA (Totally Integrated Automation)
Thanks to the optional maintenance switch it is easy to discon-
nect the converter from the network for servicing without hav-
ing to provide for additional components or additional wiring
outlay during configuration.
The optional manual on-site operation allows rapid spatially
restricted commissioning, manual pre-testing of the applica-
tion on site and validation running to be performed without ex-
pensive options
Thanks to the option of the direct connection of up to five sen-
sors to the device, almost all drive-related information can be
managed directly; a local pre-processing of the signals re-
lieves the field bus whilst ensuring a rapid and reproducible
response time
Integrated EMC filter Class A (according to EN 55011)
Integrated brake actuation, supported braking voltages
400 V AC / 180 V DC and 230 V AC / 205 V DC
Integrated motor protection thanks to thermal motor model
and evaluation of PTC, Thermo-Click or KTY 84 temperature
sensors
Simple device replacement and time-saving copying of pa-
rameters to the memory card by the optional memory card
holder and the optional MMC memory card
Engineering and commissioning with uniform engineering
tools such as SIZER (from V3.2), STARTER (from V4.1.3) and
Drive ES ensure rapid configuration and simple commission-
ing – with Drive ES Basic STARTER is integrated into STEP 7
providing the benefits of central data storage and consistent
communication
Software parameters for simple adaptation to 50 Hz or 60 Hz
motors (IEC or NEMA motors)
Increased robustness and longer service life due to painting
of the electronics assemblies
Certified worldwide according to CE, UL, c-tick
Kap_06_en.book Seite 118 Freitag, 2. September 2011 1:42 13
© Siemens AG 2011