6 © Siemens AG 2011 AS-Interface 6/2 6/2 6/4 Introduction System overview AS-Interface specification 6/6 6/6 6/8 6/11 6/14 6/15 6/17 6/21 ASIsafe Introduction AS-Interface safety monitors AS-Interface safety modules 3SF1 position switches – Plastic enclosures – Metal enclosures 3SF1 position switches with separate actuator – Plastic enclosures – Metal enclosures – Accessories 3SF1 position switches with solenoid interlocking – Plastic enclosures – Metal enclosures 3SF1 hinge switches – Plastic enclosur
© Siemens AG 2011 AS-Interface Introduction System overview Transmission technology ■ Overview AS-Interface is an open, international standard according to EN 50295 and IEC 62026-2 for process and field communication. Leading manufacturers of actuators and sensors all over the world support the AS-Interface. Interested companies are provided with the electrical and mechanical specifications by the AS-Interface Association. AS-Interface is a single master system.
© Siemens AG 2011 AS-Interface Introduction System overview Communication overview ■ Overview System components To implement the communication, a system installation has the following main components: • Master interface modules for central control units such as SIMATIC S7, ET 200 M distributed peripherals, or network transitions from PROFIBUS/PROFINET to AS-Interface • Power supply units, if required in combination with a data decoupling module for the power supply to the slaves • AS-Interface shaped cabl
© Siemens AG 2011 AS-Interface Introduction AS-Interface specification Specification 2.0, 2.1 and 3.0 ■ Overview Scope of the AS-Interface specification AS-Interface specification Maximum number of slaves Number of digital inputs Number of digital outputs Digital Analog ASIsafe DI DO Version 2.0 31 31 31 31 × 4 = 124 31 × 4 = 124 Version 2.1 62 31 31 62 × 4 = 248 62 × 3 = 186 Version 3.0 62 62 31 62 × 8 = 496 62 × 8 = 496 Basic data of AS-Interface Specification 2.
© Siemens AG 2011 AS-Interface Introduction AS-Interface specification AS-i Power24V expansion ■ Overview ■ Benefits AS-i Power24V networks incur no additional costs for an AS-Interface power supply unit because an already existing 24 V power supply unit can be used. This brings the user several benefits: • The level of standardization of very small applications can be increased further.
© Siemens AG 2011 AS-Interface ASIsafe Introduction Power supply unit NSA0_00005f ■ Overview Safety monitor AS-i POWER Standard PLC Standard-Master StandardSlave AS-Interface Safe slave with EMERGENCY STOP Signal evaluation of slave/safety monitor Secure communication and standard communication on AS-Interface Tested safety The system was tested and approved by TÜV (Germany), NRTL (USA) and INRS (France).
© Siemens AG 2011 AS-Interface ASIsafe Introduction ■ Overview (continued) Function Like the standard stations, the safe stations send their information to the master after master calls. The safety monitor monitors this transmission from the safe stations to the master and switches to the safe state or sends a disconnect signal to one or more distributed safe AS-i outputs which switch in turn to the safe state. The safety monitor provides OR logic, AND logic, timer functions, buffer storage, etc.
© Siemens AG 2011 AS-Interface ASIsafe AS-Interface safety monitors ■ Overview ■ Application The safety monitor acts as a "bus-based safety relay". It provides a user-friendly introduction to safety-orientated communication over fieldbuses thanks to its simple configuration using the graphic PC software ASIMON. The standard infrastructure of the AS-i network (AS-i master under standard PLC, AS-i power supply unit) can still be used without restriction.
© Siemens AG 2011 AS-Interface ASIsafe AS-Interface safety monitors ■ Application (continued) Features of the basic safety monitor • Wildcards and deactivating of monitoring modules Wildcards are available for the configuration. They are integrated in the configuration and diagnostics and can be easily activated if required. User-friendly configuring is thus possible even when system configurations change.
© Siemens AG 2011 AS-Interface ASIsafe AS-Interface safety monitors ■ Selection and ordering data 3RK1 105-1BE04-0CA0 Version Order No.
© Siemens AG 2011 AS-Interface ASIsafe AS-Interface safety modules ■ Overview K45F compact safety modules for operation in the field AS-Interface safety modules: K45F (left), K20F (center) and S22.5F (right) The platform of the K45F modules covers the following variations: • Connection of ("mechanical") switches/safety sensors with contacts: - K45F 2F-DI: Two safety-oriented inputs in operation up to Category 2 according to EN ISO 13849-1.
© Siemens AG 2011 AS-Interface ASIsafe AS-Interface safety modules ■ Selection and ordering data Version Order No.
© Siemens AG 2011 AS-Interface ASIsafe AS-Interface safety modules ■ Accessories Version Order No.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches ■ Overview The 3SF1 position switches with safety-oriented communication can be directly connected using the AS-Interface bus system. The safety functions no longer have to be conventionally wired up. With the 3SF1 position switches the ASIsafe electronics are integrated in the switch enclosure. Connection Connection to the AS-Interface is connected to the yellow AS-Interface bus cable by means of a 4-pole M12 plug (plastic version).
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches Plastic enclosures ■ Selection and ordering data Modular system For the ASIsafe version of the position switch, the basic switch and actuator must be ordered separately. 1 or 2 contacts · 3 LEDs · Degree of protection IP65 (31 mm) or IP66/IP67 (50 mm) · M12 plug Version Contacts LEDs Order No.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches Plastic enclosures ■ Selection and ordering data (continued) Version Diameter Order No.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches Metal enclosures ■ Selection and ordering data Modular system For the ASIsafe version of the position switch, the basic switch and actuator must be ordered separately. 2 contacts · 3 LEDs · Degree of protection IP66/IP67 · M12 plug Version Contacts LEDs Order No.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches Metal enclosures ■ Selection and ordering data (continued) Version Diameter Order No.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches Metal enclosures ■ Selection and ordering data (continued) Modular system For the ASIsafe version of the position switch, the basic switch and actuator must be ordered separately.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches Metal enclosures ■ Selection and ordering data (continued) Version Diameter Order No.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches with separate actuator ■ Overview The 3SF1 position switches with safety-oriented communication can be directly connected using the AS-Interface bus system. The safety functions no longer have to be conventionally wired up. Connection With the 3SF1 position switches the ASIsafe electronics are integrated in the switch enclosure. The wide enclosures (50 or 56 mm) also have an M12 socket for connecting a second position switch.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches with separate actuator Plastic enclosures ■ Overview • Contacts: 1 or 2 slow-action contacts • Status display with 3 LEDs 24 V DC; 1: F–IN1, 2: F–IN2, 3: AS-i/FAULT • Degree of protection IP65 (31 mm) or IP66/IP67 (50 mm) ■ Selection and ordering data Version 1) Contacts Order No.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches with separate actuator Metal enclosures ■ Overview • Contacts: 1 or 2 slow-action contacts • Status display with 3 LEDs 24 V DC; 1: F–IN1, 2: F–IN2, 3: AS-i/FAULT • Degree of protection IP66/IP67 ■ Selection and ordering data Version 1) Contacts Order No.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches with separate actuator Accessories ■ Selection and ordering data Version Order No. Actuators Standard actuators Standard actuators, length 75.6 mm q 3SE5 000-0AV01 With vertical fixing, length 53 mm q 3SE5 000-0AV02 With transverse fixing, length 47 mm q 3SE5 000-0AV03 With transverse fixing, plastic1) Length 47 mm q 3SE5 000-0AW11 Approach from left, length 40 mm q 3SE5 000-0AV04 Approach from right, length 44.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches with solenoid interlocking ■ Overview The 3SF1 position switches with safety-oriented communication can be directly connected using the AS-Interface bus system. The safety functions no longer have to be conventionally wired up. With the 3SF1 position switches the ASIsafe electronics are integrated in the switch enclosure.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches with solenoid interlocking Plastic enclosures ■ Overview 5 directions of approach · Degree of protection IP66/IP67 • Slow-action contacts: - Version -1BA1: ASIsafe channel 1 on 1 NC contact from the actuator and channel 2 on 1 NC contact from the solenoid - Version -1BA3: ASIsafe channel 1 on the first NC contact from the actuator and channel 2 on the second NC contact from the actuator - Version -1BA4: ASIsafe channel 1 on 2 NC contacts from t
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 position switches with solenoid interlocking Metal enclosures ■ Overview 5 directions of approach · Degree of protection IP66/IP67 • Slow-action contacts: Version -1BA1: ASIsafe channel 1 on 1 NC contact from the actuator and channel 2 on 1 NC contact from the solenoid • Solenoid: Rated operational voltage 24 V DC • Locking force 2600 N (2000 N according to GS-ET 19) • Status display with 4 LEDs 24 V DC; 1: AS-i, 2: FAULT, 3: F–IN1, 4: F–IN2 Safety level Version
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 hinge switches Plastic enclosures ■ Overview The 3SF1 hinge switches with safety-oriented communication can be directly connected using the AS-Interface bus system. The safety functions no longer have to be conventionally wired up. For the ASIsafe version of the hinge switch, the basic switch and twist actuator must be ordered separately.
© Siemens AG 2011 AS-Interface ASIsafe 3SF1 hinge switches Metal enclosures ■ Overview The 3SF1 hinge switches with safety-oriented communication can be directly connected using the AS-Interface bus system. The safety functions no longer have to be conventionally wired up. For the ASIsafe version of the hinge switch, the basic switch and twist actuator must be ordered separately. The basic switches correspond to the position switches of the standard version (only use versions with snap-action contacts).
© Siemens AG 2011 AS-Interface ASIsafe 3SF2 cable-operated switches for AS-Interface ■ Overview SIRIUS cable-operated switches are used for monitoring or for EMERGENCY-STOP devices on particularly endangered system sections. AS-Interface cable-operated switches can be directly connected via the bus system AS-Interface with safety-oriented communication. The safety functions no longer have to be conventionally wired up.
© Siemens AG 2011 AS-Interface ASIsafe SIRIUS EMERGENCY-STOP mushroom pushbuttons for AS-Interface ■ Overview EMERGENCY-STOP control devices can now be directly connected via the standard AS-Interface with safety-oriented communication. This only applies for the SIRIUS 3SB3 EMERGENCY-STOP mushroom pushbutton for front panel mounting and for mounting into an enclosure. AS-Interface EMERGENCY-STOP enclosures The enclosure is delivered fully equipped and wired up.
© Siemens AG 2011 AS-Interface ASIsafe SIRIUS EMERGENCY-STOP mushroom pushbuttons for AS-Interface ■ Selection and ordering data EMERGENCY-STOP control device acc. to ISO 13850 and IEC 60947-5-5 • With holder for mounting on front plates • Connection with F adapter AS-Interface • Yellow backing plates are to be ordered separately Version Approval Order No.
© Siemens AG 2011 AS-Interface ASIsafe SIRIUS EMERGENCY-STOP mushroom pushbuttons for AS-Interface ■ Selection and ordering data (continued) EMERGENCY-STOP control device acc. to ISO 13850 and IEC 60947-5-5 • With holder for mounting on front plates • Connection with F adapter AS-Interface • Yellow backing plates are to be ordered separately Version Approval Order No.
© Siemens AG 2011 AS-Interface ASIsafe AS-Interface F adapters for EMERGENCY-STOP devices ■ Overview The AS-Interface F adapter is used to connect an EMERGENCY-STOP device according to ISO 13850 from the 3SB3 series to the AS-Interface bus system. The F adapter is suitable for control devices with mounting on front plates.
© Siemens AG 2011 AS-Interface Masters Masters for SIMATIC S7 CP 243-2 ■ Overview Design The CP 243-2 is connected like an expansion module to the S7-200.
© Siemens AG 2011 AS-Interface Masters Masters for SIMATIC S7 CP 343-2P, CP 343-2 ■ Overview Design The CP 343-2P / CP 343-2 is connected like an I/O module to the S7-300.
© Siemens AG 2011 AS-Interface Masters Masters for SIMATIC S7 CP 343-2P, CP 343-2 ■ Application The CP 343-2P / CP 343-2 is the AS-Interface master connection for the SIMATIC S7-300 and the ET 200M. Through connection to AS-Interface it is possible to access max. 248 DI/248 DO per CP, using 62 A/B slaves with 4DI/4DO each.
© Siemens AG 2011 AS-Interface Network transitions DP/AS-i LINK Advanced ■ Overview Functionality Communication The DP/AS-i LINK Advanced enables a PROFIBUS DP master to cyclically access the I/O data of all the slaves of a lower-level AS-Interface segment. Also supported are the expanded slave types with higher I/O data volume according to AS-i Specification V3.0.
© Siemens AG 2011 AS-Interface Network transitions DP/AS-i LINK Advanced ■ Benefits • Short start-up times through simple configuration at the press of a button and testing of the AS-Interface line using the display or web interface • Reduction of standstill and servicing times in the event of a slave failure thanks to user-friendly diagnostics using the display or web interface and through simple module exchange with the help of the C-PLUG exchange medium • Reduced amount of engineering work thanks to u
© Siemens AG 2011 AS-Interface Network transitions DP/AS-i LINK Advanced ■ Selection and ordering data Version Combicon connection Order No. DP/AS-i LINK Advanced Network transition between PROFIBUS DP and AS-Interface; Degree of protection IP20; including COMBICON plug-in screw terminals for connection of an AS-Interface cable (two AS-Interface cables for double masters) and the optional 24 V supply; corresponds to AS-Interface Specification 3.0; dimensions (W x H x D / mm): 90 x 132 x 88.
© Siemens AG 2011 AS-Interface Network transitions DP/AS-Interface Link 20E ■ Overview Design • Compact plastic enclosure in degree of protection IP20 for standard rail mounting • LEDs in the front panel for indicating the operating state and functional readiness of all connected slaves • Setting option for PROFIBUS DP address by pressing a button • LED indication of the PROFIBUS DP slave address, DP bus faults and diagnostics • Two pushbuttons for switching over the operating state and for adopting the e
© Siemens AG 2011 AS-Interface Network transitions DP/AS-Interface Link 20E ■ Application (continued) PC/IPC with CP 5621 S7-400 E.g. with CP 443-5 Extended S7-300 with DP-Master PROFIBUS DP/AS-Interface Link 20E LOGO! Power supply Safe slave with EMERGENCY STOP Digital/analog slaves Compact starter 3RA6 Laser scanners Safety monitor Transition from PROFIBUS DP to AS-Interface using DP/AS-Interface Link 20E 6 ■ Selection and ordering data Version Screw terminals Order No.
© Siemens AG 2011 AS-Interface Network transitions DP/AS-i F-Link ■ Overview Design • Rugged, slim plastic enclosure, degree of protection IP20, for standard rail mounting or wall mounting (with adapter) • Compact design: - LEDs in the front panel for indicating the operating state and functional readiness of all connected slaves - 2 buttons on the front for start-up and call up of diagnostics information - 4 LEDs for indication of the operating state of the device, of PROFIBUS DP and the AS-Interface net
© Siemens AG 2011 AS-Interface Network transitions DP/AS-i F-Link ■ Benefits ■ Application Links between PROFIsafe and ASIsafe 6 • Gaps in (bus-based) safety technology closed: safetyoriented signals (EMERGENCY-STOP, door tumbler, light curtains etc.) collected with AS-i and transferred to higherlevel F-PLC.
© Siemens AG 2011 AS-Interface Network transitions DP/AS-i F-Link ■ Application (continued) Network connectivity The DP/AS-i F-Link can be used in PROFIBUS and PROFINET networks as follows: HMI SIMATIC S7-300F PROFIBUS F-DI AI/AO DI/DO SIMATIC ET 200S DP/AS-i F-Link (Spec. 3.
© Siemens AG 2011 AS-Interface Network transitions DP/AS-i F-Link ■ Application (continued) Further network connectivity options: • Integration in PROFINET networks under SIMATIC F PLC through IE/PB Link • Integration in SINUMERIK Power Line and Solution Line • Integration under non-Siemens failsafe control systems using PROFIBUS GSD file, available on the Internet at http://support.automation.siemens.com/WW/view/en/113250 ■ Selection and ordering data Version Order No.
© Siemens AG 2011 AS-Interface Network transitions IE/AS-i LINK PN IO ■ Overview Functionality Communication The IE/AS-i LINK PN IO enables a PROFINET IO controller to cyclically access the I/O data of all the slaves of a lower-level AS-Interface segment. Also supported are the expanded slave types with higher I/O data volume according to AS-i Specification V3.0.
© Siemens AG 2011 AS-Interface Network transitions IE/AS-i LINK PN IO ■ Benefits • Short start-up times through simple configuration at the press of a button and testing of the AS-Interface line using the display or web interface • Reduction of standstill and servicing times in the event of a slave failure thanks to user-friendly diagnostics using the display or web interface • Costs saved by the double AS-Interface master when large volumes of project data are involved • Saves the need for AS-i power p
© Siemens AG 2011 AS-Interface Network transitions IE/AS-i LINK PN IO ■ Application (continued) Wireless communication Using an upstream IWLAN client module, e. g. SCALANCE W746-1PRO, an AS-Interface line can be integrated in the PROFINET world by wireless means. Sample uses are applications which up to now have been performed with fault-prone tow chain or collector wire technology. Maintenance costs are thus reduced.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Digital I/O modules, IP67 - Introduction ■ Overview K60 K20 Three coordinated series of AS-Interface compact modules with digital and analog compact modules and a high degree of protection are available for operation in the field: • Series K60 (digital and analog) • Series K45 (digital) • Series K20 (digital) All compact modules are characterized by particularly simple handling.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Digital I/O modules, IP67 - K60 ■ Overview The K60 digital AS-Interface compact modules are characterized by optimized handling characteristics and user-friendliness. They permit the mounting times and start-up times of AS-Interface to be reduced by up to 40 %. Assembly of the K60 modules is performed with a mounting plate which accommodates the AS-Interface shaped cables.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Digital I/O modules, IP67 - K60 ■ Selection and ordering data Version Order No.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Digital I/O modules IP68/IP69K - K60R ■ Overview Operation in particularly harsh environments Connection NSA0_00339d K60R IP68 K60R IP68 K60R IP68 Distributor K60R module in degree of protection IP68/IP69K Modules with degree of protection IP67 cannot be used in areas exposed to permanently high levels of humidity, in applications with drilling emulsions and cutting oils or when cleaning with hig
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Digital I/O modules IP68/IP69K - K60R ■ Overview (continued) • Test with drilling emulsion: Five months at room temperature (components of the drilling emulsion: Anionic and non-ionic emulsifiers, paraffinic low-aromatic mineral oil, boric acid alkanolamines, corrosion inhibitors, oil content 40 %) • Test in oil bath (Excelence 416 oil) with alternating oil bath temperature: 130 cycles of 15 to 55 °C, t
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Digital I/O modules, IP67 - K45 ■ Overview Two mounting plates are offered for the K45 compact modules: • The mounting plate for wall mounting has a hole pattern that is identical to that of the K60 compact modules. This means that K60 compact modules can be mounted together with K45 modules in an aligned arrangement.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Digital I/O modules, IP67 - K45 ■ Selection and ordering data Version Order No.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Digital I/O modules IP67 - K20 ■ Overview The flexibility of the round cable means that it can also be used on moving machine parts without any problems. The K20 modules are also ideal for such applications as their non-encapsulated design makes them particularly light in weight. In applications with tow chains, many users rely on placing the AS-Interface bus cable in a round cable.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Digital I/O modules IP67 - K20 ■ Selection and ordering data (continued) Version Order No.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Digital I/O modules, IP67 - user modules ■ Overview The AS-Interface user modules are the first module generation for AS-Interface. Today, innovated and further improved modules are available in the form of the K45 and K60 series of compact modules. We recommend replacing the user modules in future with the K45 compact module series.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Analog I/O modules, IP67 - K60 ■ Overview ■ Benefits • Analog modules are just as easy to integrate in AS-Interface as digital modules • Analog values can be easily detected and issued locally • Preprocessing of the analog value transmission in the master enables rapid evaluation of the analog values • Up to four values can be detected using one analog module • Faster transmission and conversion of ana
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Analog I/O modules, IP67 - K60 ■ Selection and ordering data Version Order No. Analog I/O modules IP67 – K60, analog profile 7.3 • Slave type: Standard • Width 60 mm • Modules supplied without mounting plate Inputs Type 1 or 2 inputs Current (selectable using jumper plug at socket 3) 3RK1 207-1BQ44-0AA3 4 inputs Outputs 2 outputs Measuring range 4 ...
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the field, high degree of protection Analog I/O modules, IP67 - K60 ■ Selection and ordering data (continued) Version Order No. Accessories Manuals Only available to download on the Internet: www.siemens.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the control cabinet Introduction ■ Overview SlimLine S22.5/S45 Flat module For AS-Interface applications inside control cabinets there are various module series for the most diverse requirements: • SlimLine S22.5 • SlimLine S45 • F90 module • Flat module All modules of these series can be snap-mounted directly on a standard mounting rail or be fastened using screws.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the control cabinet SlimLine ■ Overview SlimLine modules of the S22.5 and S45 series An addressing socket integrated at the front enables the module to be addressed also when it is installed. In addition to the digital input/output modules there are modules of design S22.5 with special functions.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the control cabinet SlimLine ■ Selection and ordering data Version Order No. S22.5 SlimLine modules • Inputs: PNP transistor • Width 22.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the control cabinet F90 module ■ Selection and ordering data Version Order No.
© Siemens AG 2011 AS-Interface slaves I/O modules for operation in the control cabinet Flat module ■ Selection and ordering data Version Screw terminals Order No.
© Siemens AG 2011 AS-Interface slaves Special integrated solutions AS-Interface communication modules ■ Overview AS-Interface communication modules for printed circuit board installation 3RK1 400-0CD01-0AA3 AS-Interface communication modules for printed circuit board installation aux NC + IN1 OUT1 0 IN2 OUT2 0 IN3 OUT3 0 IN4 OUT4 0 + ASI– ASI+ NSA0_00079a 6 AS-Interface 3RK1 400-0CD00-0AA3 communication module (left) AS-Interface 3RK2 400-1FD00-0AA2 communication cable (right) 3RK1 400-0CD01-0AA3 3
© Siemens AG 2011 AS-Interface slaves Special integrated solutions AS-Interface communication modules ■ Overview (continued) 3RK1 400-1CD00-0AA2, 3RK2 400-1FD00-0AA2 AS-Interface communication modules for printed circuit board installation Connection Connection pad 1) AS-i + AS-i - 3RK1 200-0CD00-0AA2 AS-Interface communication modules for printed circuit board installation Connection Connection pad 1) 27, 29 AS-i + 27, 29 28, 30 AS-i - 28, 30 Sensor+ 17, 18, 23, 24 Sensor+ 17, 18, 23, 24 S
© Siemens AG 2011 AS-Interface slaves Modules with special functions Counter modules ■ Overview U IN 1 N S A 0 0 0 8 4 ³ 3 0 0 ³ 1 m s s t Maximum frequency for the counter module If the time criterion stipulated in the graphic is violated, the count value is rejected. The counter is active only for the reset parameter P2 (default). The counter is deleted when P2 is set, and the incoming count pulses are not registered until after P2 is reset again.
© Siemens AG 2011 AS-Interface slaves Modules with special functions Ground-fault detection modules ■ Overview "Ground faults in any control circuit must not lead to unintentional starting or potentially hazardous movements or prevent the machine from stopping." (EN 60204-1 / VDE 0113-1). The AS-Interface ground-fault detection module is used to meet these requirements. Using this module from the SlimLine series, ground faults in AS-Interface systems can be reliably detected and reported.
© Siemens AG 2011 AS-Interface slaves Modules with special functions Overvoltage protection module ■ Overview (continued) Configuration guidelines ASInterface OVP ASInterface Application NSA0_00093a Device without ground terminal → Grounding of the mounting plate Application Device with ground terminal Mounting plate OVP = Overvoltage protection Configuration guidelines for overvoltage protection modules The grounding of protection modules and the units to be protected must be effected through
© Siemens AG 2011 AS-Interface slaves Slaves AS-Interface connections for LOGO! ■ Overview Every LOGO! can now be connected to the AS-Interface system Using the AS-Interface connection for LOGO!, an intelligent slave can be integrated in the AS-Interface system. With the modular interface it becomes possible to integrate the different basic units in the system according to their functionality. Similarly, functionalities can be quickly and easily adapted to new requirements by exchanging the basic unit.
© Siemens AG 2011 AS-Interface slaves Contactors and contactor assemblies — Power contactors for switching motors SIRIUS 3RT20 contactors ■ Overview Contactors with communication interface, sizes S00 and S0 Contactor versions with a communication interface are required for the connection to the controller via IO-Link or AS-Interface. The connection is made via function modules, which are mounted on to the front side of the contactors.
© Siemens AG 2011 AS-Interface slaves Contactors and Contactor Assemblies SIRIUS 3RA24 contactor assemblies for wye-delta starting ■ Overview These 3RA24 contactor assemblies for wye-delta starting are designed for standard applications. Note: Contactor assemblies for wye-delta starting in special applications such as very heavy starting or wye-delta starting of special motors must be customized. Help with designing such special applications is available from Technical Assistance.
© Siemens AG 2011 AS-Interface slaves Contactors and Contactor Assemblies SIRIUS 3RA27 function modules for AS-Interface ■ Overview The function modules for mounting onto contactors enable the assembly of starters and contactor assemblies for direct-on-line, reversing and wye-delta starting without any additional, complicated wiring of the individual components.
© Siemens AG 2011 AS-Interface slaves Contactors and Contactor Assemblies SIRIUS 3RA27 function modules for AS-Interface ■ Selection and ordering data (continued) Version Screw terminals Spring-type terminals Order No. Order No.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders General data ■ Overview 3RA6 fuseless compact feeders and infeed system for 3RA6 Communications integration using IO-Link SIRIUS 3RA64, 3RA65 compact feeders for IO-Link see Chapter 7: "IO-Link". Permanent wiring/easy replacement Using the SIRIUS infeed system for 3RA6 it is possible to carry out the wiring in advance without a compact feeder needing to be connected.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders General data ■ Overview (continued) Type of infeed Feeder terminal Type (acc.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders General data ■ Overview (continued) Available for the 3RA61 and 3RA64 direct-on-line starters is a slot for an optional auxiliary switch block (optionally 2 NO, 2 NC or 1 NO + 1 NC) and for the 3RA62 and 3RA65 reversing starters there are two slots (for auxiliary switch blocks see "Accessories" on Page 6/84).
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet 3RA61, 3RA62 compact feeders 3RA61 direct-on-line starters ■ Selection and ordering data Direct-on-line start Width 45 mm Rated short-circuit current ICS = 53 kA at 400 V A set of 3RA69 40-0A adapters is required for screw fixing.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet 3RA61, 3RA62 compact feeders 3RA62 reversing starters ■ Selection and ordering data Width 90 mm Reversing duty Rated short-circuit current ICS = 53 kA at 400 V Two sets of 3RA69 40-0A adapters are required for screw fixing.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Accessories ■ Overview Accessories for SIRIUS 3RA6 compact feeders Busbar adapters for 60 mm systems The following accessories are available specially for the 3RA6 compact feeders: • AS-i add-on module: see from Page 6/88 "AS-interface add-on modules" • External auxiliary switch blocks: Snap-on auxiliary switch as versions 2 NO, 2 NC and 1 NO + 1 NC with screw or springtype connections;
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Accessories ■ Selection and ordering data Version Order No. Accessories specially for 3RA6 compact feeders Control kit 3RA69 50-0A For mechanical actuation of the compact feeder 3RA69 50-0A Adapters for screw fixing the compact feeder (set including push-in lugs) 3RA69 40-0A Direct-on-line starters require one set, reversing starters two sets.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Accessories ■ Selection and ordering data (continued) Version Order No. Accessories specially for 3RA6 compact feeders (continued) Main circuit terminals mixed connection method 3RA69 20-3A 1 set comprises: • 1 joint block on the line side with screw terminals • 1 joint block on the outgoing side with spring-type terminals 3RA69 20-3A Version Order No.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Accessories ■ Selection and ordering data (continued) Conductor cross-section Solid or stranded Finely stranded with end sleeve AWG cables, solid or stranded Tightening torque For compact feeders and motor starter protectors mm² AWG Nm Size Order No. 10-4 4 S0 3RV19 25-5AB 10-4 Input: 4; Output: 2 ... 2.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Accessories ■ Selection and ordering data (continued) Version Order No. Tools for opening spring-type terminals 3RA29 08-1A Screwdrivers for all SIRIUS devices with spring-type terminals Spring-type terminals Length approx. 200 mm, 3.0 mm x 0.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Add-on modules for AS-Interface ■ Overview The AS-i add-on modules can be combined only in connection with compact feeders with a rated control supply voltage of 24 V AC/DC.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Add-on modules for AS-Interface ■ Selection and ordering data Version Order No. Standard version 3RA69 70-3A AS-i add-on modules For communication of the compact feeder with the control system using AS-Interface With two local inputs 3RA69 70-3B For safe disconnection through local safety relays, e.g.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Infeed system for 3RA6 ■ Overview In addition, the integrated PE bar means it is optionally possible to connect the motor cable directly to the infeed system without additional intermediate terminals. The infeed system for 3RA6 compact feeders is designed for summation currents up to 100 A with a maximum conductor cross-section of up to 70 mm² on the feeder terminal block.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Infeed system for 3RA6 ■ Overview (continued) $ Infeed - End covers The 3-phase infeed is available with screw connection (25/35 mm2 up to 63 A or 50/70 mm2 up to 100 A) and springtype connection (25/35 mm2 up to 63 A). On the last expansion module of a row, the socket provided for the expansion plug can be covered by inserting the end cover.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Infeed system for 3RA6 ■ Overview (continued) Maximum rated operational current Proposal for upstream short-circuit protection devices The following maximum rated operational currents apply for the components of the infeed system for 3RA6: The following short-circuit data apply for the components of the infeed system for 3RA6 compact feeders: Component Maximum rated operational curren
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Infeed system for 3RA6 ■ Selection and ordering data Version Order No.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Infeed system for 3RA6 ■ Selection and ordering data (continued) Version Order No. Expansion modules Two-socket expansion modules with screw or spring-type terminals and integrated PE bar with 2 sockets for 2 direct-on-line starters or 1 reversing starter Expansion plug and 2 connecting wedges are included in the scope of supply.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Infeed system for 3RA6 ■ Selection and ordering data (continued) Version Order No.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the control cabinet SIRIUS 3RA6 compact feeders Infeed system for 3RA6 ■ Selection and ordering data (continued) Version Order No.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection SIRIUS M200D motor starters General data ■ Overview Basic functionality SIRIUS M200D AS-i Basic motor starters with manual on-site operation The intelligent, highly flexible SIRIUS M200D motor starters for distributed configurations are designed to start, monitor and protect motors and loads up to 5.5 kW.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection SIRIUS M200D motor starters M200D motor starters for AS-Interface ■ Overview For motor control using AS-Interface there are the following M200D motor starter versions: SIRIUS M200D AS-i Basic and SIRIUS M200D AS-i Standard (for details of basic functionality see Page 6/97 "M200D motor starters" --> "General data" --> "Overview").
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection SIRIUS M200D motor starters M200D motor starters for AS-Interface ■ Overview (continued) SIRIUS M200D SIRIUS M200D AS-i Basic AS-i Standard Device functions (firmware features) Slave on the bus Fieldbus ✓ AS-i Slave type ✓ A/B acc. to Spec 2.1 ✓ A/B acc. to Spec 3.0 Profile ✓ 7.A.E ✓ 7.A.E & 7.A.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection SIRIUS M200D motor starters M200D motor starters for AS-Interface ■ Overview (continued) SIRIUS M200D SIRIUS M200D AS-i Basic AS-i Standard Device functions (firmware features) Device functions Repair switch ✓ Current limit monitoring bottom -- ✓ Parameterizable Current limit monitoring top -- ✓ Parameterizable Zero current detection ✓ Permanent function: disconnection, less than 18.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection M200D motor starters for AS-Interface M200D Basic motor starters ■ Selection and ordering data M200D AS-i Basic without manual on-site operation M200D AS-i Basic with manual on-site operation Version Order No. Version Order No.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection M200D motor starters for AS-Interface M200D Standard motor starters ■ Selection and ordering data M200D AS-i Standard without manual on-site operation M200D AS-i Standard with manual on-site operation Version Order No. Version Order No.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection SIRIUS M200D motor starters Accessories ■ Overview 7 NSA0_00484 NSA0_00485a 1 2 9 4 10 5 3 6 M 8 1 Power feeder plug 7 Connection for motor control with AS-i communication 2 Power connection plug 8 AS-Interface M12 feeder 3 Incoming energy supply cable 9 Connection for digital input 4 Motor connection plug 5 Motor plug 6 Motor cable Power and motor connection on the M20
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection SIRIUS M200D motor starters Accessories ■ Selection and ordering data The accessories listed below represent a basic selection sorted by: • Accessories for all M200D motor starters • Accessories for M200D motor starters for AS-interface Note: More connection technology products can be found at "Siemens Solution Partners Automation" under the "Distributed Field Installation System" technology.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection SIRIUS M200D motor starters Accessories ■ Selection and ordering data (continued) Version Order No. Motor control with IO communication 1) M12 plugs Screw fixing, 5-pole screw terminals, max. 0.75 mm2, A-coded, max. 4 A 3RK1 902-4BA00-5AA0 . M12 plugs, angled Screw fixing, 5-pole screw terminals, max. 0.75 mm2, A-coded, max.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection SIRIUS M200D motor starters Accessories ■ Selection and ordering data (continued) Version Order No. Only for M200D motor starters for AS-interface Motor control with AS-i communication 1) + Control cables, assembled at one end Angular M12 socket, screw fixing, 4-pole, 4 x 0.34 mm2, A-coded, black PUR sheath, max.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection SIRIUS MCU motor starters General data ■ Overview 3RK43 20-3.R51-.BA0 3RK43 20-3.Q54-.BA. Portfolio of the SIRIUS 3RK43 MCU motor starter family The SIRIUS MCU motor starter family (MCU = Motor Control Unit) rounds off the bottom end of the SIRIUS motor starter range.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection SIRIUS MCU motor starters General data ■ Overview (continued) 3RK43 20-3.R51-.BA0 Type 3RK43 20-3.Q54-.BA. 3RK43 20-5.Q64-.BA.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection MCU motor starters for AS-Interface Plastic enclosures, electromechanical switching ■ Overview 2 3 1 nsb0_02039 MCU for AS-i, plastic enclosure • Direct-on-line or reversing starters up to 12 A at 400 V AC (50/60 Hz) • Repair switches (black/gray) lockable with padlocks (max.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection MCU motor starters for AS-Interface Metal enclosures, electromechanical switching ■ Overview 6 6/110 Siemens IK PI · 2012 1 5 6 3 2 4 nsb0_02040 MCU for AS-i, metal enclosure, electromechanical • Direct-on-line or reversing starters up to 12 A • Repair switches (black/gray) lockable with padlocks (max.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection MCU motor starters for AS-Interface Metal enclosures, electromechanical switching ■ Selection and ordering data Rated current Ie Suitable for three-phase induction motors 1) with P Setting range Thermal overload release A kW A Order No. 0.63 0.18 0.45 ... 0.63 3RK43 20-3AQ54- 0BA7 0.8 0.18 0.55 ... 0.8 3RK43 20-3BQ54- 0BA7 1 0.25 0.7 ... 1 3RK43 20-3CQ54- 0BA7 1.25 0.37 0.9 ...
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection MCU motor starters for AS-Interface Metal enclosures, electronic switching ■ Overview 6 9 1 5 6 3 2 nsb0_02041 MCU for AS-i, metal enclosure, electronic • Direct-on-line or reversing starters up to 12 A • Switching frequency up to 3 600/h • Repair switches (black/gray) lockable with padlocks (max.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection MCU motor starters for AS-Interface Accessories ■ Overview The MCU motor starters are equipped with standardized interfaces for data and energy (option). Notes: See "Energy communication field installation system" for further information about the field and power bus methods for decentral installation in a high degree of protection.
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection Motor starters for AS-Interface, 24 V DC General data ■ Overview Quick-stop function All AS-Interface 24 V DC motor starters feature a quick-stop function which can be switched on and off as required using a switch integrated into the module. The quick-stop function allows a connected motor to be disconnected immediately using an applied sensor signal (High).
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection Motor starters for AS-Interface, 24 V DC General data ■ Overview (continued) Applications Single direct starter without brake (with adjustable quick-stop function) 1st possibility: Connection to a maximum of four sensors without pollution indication Sensor signal Sensor signal Sensor signal Sensor signal 4 2 Input 1 4 Input 2 2 Output off on Quick-stop for output on/off Sensor 1 Sensor 2 Senso
© Siemens AG 2011 AS-Interface slaves Motor starters for operation in the field, high degree of protection Motor starters for AS-Interface, 24 V DC General data ■ Selection and ordering data Version Inputs/outputs Current carrying capacity of outputs Slave type A Order No.
© Siemens AG 2011 AS-Interface slaves SINAMICS G110D distributed frequency converters General data ■ Overview The new distributed frequency converter series SINAMICS G110D is the solution for demanding drive applications, particularly in the field of conveyor applications. The converter permits continuous speed control of three-phase asynchronous motors and meets the requirements of conveyor applications with frequency control.
© Siemens AG 2011 AS-Interface slaves SINAMICS G110D distributed frequency converters General data ■ Benefits 6 • Wide performance range from 0.75 kW to 7.5 kW • Rapid commissioning and maintenance thanks to expanded diagnostics functions and communication capability with AS-Interface in accordance with Specification 3.
© Siemens AG 2011 AS-Interface slaves SINAMICS G110D distributed frequency converters General data ■ Application SINAMICS G110D is perfectly suited for simple conveyor applications in an industrial environment in which a distributed drive with communication capability is required. This is particularly true for distribution logistics and for airports. SINAMICS G110D is also suitable for many other lower-performance applications in many fields, e.g.
© Siemens AG 2011 AS-Interface slaves SINAMICS G110D distributed frequency converters General data ■ Selection and ordering data (continued) Order No.
© Siemens AG 2011 AS-Interface slaves 3SF5 pushbuttons and indicator lights AS-Interface enclosures and front panel modules General data ■ Overview Installation of AS-Interface slaves The following slave types are available for connecting the command points: • Slave in A/B technology with 4 inputs and 3 outputs • Slave with 4 inputs and 4 outputs • F Slave with two secure inputs for EMERGENCY-STOP mushroom pushbutton The following table shows the maximum number of equippable slaves: Distributed command d
© Siemens AG 2011 AS-Interface slaves 3SF5 pushbuttons and indicator lights AS-Interface enclosures and front panel modules With standard fittings ■ Overview Enclosures with standard fittings are available with: • 1 to 3 command points • Operational voltage through AS-Interface (approx. 30 V) • Vertical mounting type • Plastic enclosures are equipped with plastic actuators and indicators, metal enclosures are equipped with metal actuators and indicators.
© Siemens AG 2011 AS-Interface slaves 3SF5 pushbuttons and indicator lights AS-Interface enclosures and front panel modules Components ■ Selection and ordering data For self-equipping of the enclosures Version With plastic enclosure 3SF5 500-0BA AS-Interface slaves F slave, 2 safe inputs, for plastic enclosure, EMERGENCY-STOP, without protective collar F slave, 2 safe inputs, for plastic or metal enclosure, EMERGENCY-STOP, with protective collar A/B slave, 4I/3O for plastic enclosure Slave, 4I/4O, for p
© Siemens AG 2011 AS-Interface slaves 3SF5 pushbuttons and indicator lights AS-Interface enclosures and front panel modules Customized equipment ■ Overview Connection The customized enclosure is delivered fully equipped and wired. For connection to AS-Interface can be selected between: • Terminal for shaped AS-Interface cable. The cable is contacted by the insulation piercing method and routed past the enclosure on the outside (possible only with plastic enclosure).
© Siemens AG 2011 AS-Interface slaves 3SF5 pushbuttons and indicator lights AS-Interface enclosures and front panel modules Front panel module ■ Overview AS-Interface cable NSD0_00053b Terminal With the AS-Interface front panel module, 3SB3 control devices, which are mounted on to the front panels, can be connected to the AS-Interface bus system. Plastic or metal pushbuttons or indicator lights in round or square design can be used. Mushroom pushbuttons and acoustic signaling devices cannot be used.
© Siemens AG 2011 AS-Interface slaves 3SF5 pushbuttons and indicator lights AS-Interface enclosures and front panel modules Front panel module ■ Selection and ordering data can be obtained from the list of options that are subject to a surcharge. To order the front panel module, please fill out the order form and include it with your order. These order documents cannot be generated via the 3SB3/3SF5 configurator. The electronic order form is available from our Technical Support: Tel.
© Siemens AG 2011 AS-Interface slaves 3SF5 pushbuttons and indicator lights AS-Interface enclosures and front panel modules Front panel module ■ Selection and ordering data (continued) Selection of equipping options according to order documentation Version Code according to colors Black Red Yellow Green Blue White Clear Actuators and indicators Pushbuttons with flat button D Illuminated pushbuttons with flat button – BK D RD D YE D GN D BU D WH D CL DL RD DL YE DL GN DL BU
© Siemens AG 2011 AS-Interface slaves 3SF5 pushbuttons and indicator lights AS-Interface enclosures and front panel modules Front panel module ■ Selection and ordering data (continued) Selection of equipping options according to order documentation Version Code Key can be removed in any position O I II O and I O and II I and II I, O and II Key-operated switches with 2 switch positions Switching sequence O–I, latching RONIS type: Lock No.
© Siemens AG 2011 AS-Interface slaves 3SF5 pushbuttons and indicator lights AS-Interface enclosures and front panel modules Front panel module ■ Selection and ordering data (continued) Selection of equipping options according to order documentation Version Code Key can be removed in any position O I II O and I O and II I and II I, O and II Key-operated switches with 3 switch positions Switching sequence I–O–II, latching to the right, momentary contact to the left RONIS type: Lock No.
© Siemens AG 2011 AS-Interface slaves 8WD4 signaling columns General data ■ Overview The 8WD4 signaling columns are flexible in design and versatile in use. These are used for controlling complex processes in machines or automated processes or as visual or acoustic warning systems in emergency situations, e.g. for displaying individual stages of production.
© Siemens AG 2011 AS-Interface slaves 8WD4 signaling columns 8WD42 signaling columns, 50 mm diameter ■ Selection and ordering data Version Rated voltage Color Order No. Buzzer element 80 dB, Sound type pulsing or continuous tone, can be adjusted via a wire jumper 24 V AC/DC Black 8WD42 20-0FA 24 ...
© Siemens AG 2011 AS-Interface slaves 8WD4 signaling columns 8WD42 signaling columns, 50 mm diameter ■ Selection and ordering data (continued) Version Order No. Mounting Feet, single 8WD43 08-0DB Metal, for pipe lengths > 400 mm 8WD43 08-0DC Plastic, for floor mounting (without pipe) 8WD42 08-0DE Foldaway base for positioning in the grid 7.5° 1) Plastic, for mounting on pipes, incl.
© Siemens AG 2011 AS-Interface slaves 8WD4 signaling columns 8WD44 signaling columns, 70 mm diameter ■ Selection and ordering data Version Rated voltage Color Order No.
© Siemens AG 2011 AS-Interface slaves 8WD4 signaling columns 8WD44 signaling columns, 70 mm diameter ■ Selection and ordering data (continued) Version Order No. Mounting 6 Foot with pipe Pipe length 100 mm 8WD43 08-0DA Feet, single Plastic, for mounting on pipes 8WD43 08-0DB Metal, for pipe lengths > 400 mm 8WD43 08-0DC Foldaway base for positioning in the grid 7.5° 1) Plastic, for mounting on pipes, incl.
© Siemens AG 2011 AS-Interface Power supply units and data decoupling modules AS-Interface power supply units ■ Overview AS-Interface power supply unit for 3A AS-Interface power supply units feed 30 V DC into the AS-Interface cable and supply the AS-Interface components. They include power-optimized data decoupling for the separation of communication signals and control supply voltage. As the result, AS-Interface is able to convey both data and power along a single line.
© Siemens AG 2011 AS-Interface Power supply units and data decoupling modules S22.
© Siemens AG 2011 AS-Interface Power supply units and data decoupling modules S22.5 data decoupling modules ■ Application (continued) Construction of an AS-i Power24V network with an AS-Interface S22.
© Siemens AG 2011 AS-Interface Transmission media AS-Interface shaped cables ■ Overview To enable use in the most varied ambient conditions (e. g. in an oily environment), the AS-Interface cable is available in different materials (rubber, TPE, PUR). For special applications it is also possible to use an unshielded standard round cable H05VV-F 2x1.5 mm² according to AS-i Specification. With AS-Interface, data and energy for the sensors (e.g. proximity switches BERO) and actuators (e. g.
© Siemens AG 2011 AS-Interface System components and accessories Repeater ■ Overview ■ Benefits • More possibilities of use and greater freedom for plant planning through extension of the AS-Interface network • Reduced downtime and servicing times in the event of a fault thanks to separate indication of the correct AS-Interface voltage for each side ■ Application The repeater is used to lengthen the AS-Interface segment by 100 m.
© Siemens AG 2011 AS-Interface System components and accessories Extension plug ■ Overview The extension plug is a passive component, the extension plug plus is equipped in addition with an A/B slave. The extension plug / extension plug plus has an M12 plug and can be connected with it to the AS-Interface M12 feeder with degree of protection IP67. Only one power supply unit is needed to supply power to the slaves on the up to 200 m long segment.
© Siemens AG 2011 AS-Interface System components and accessories Addressing units ■ Overview New addressing unit V 3.0 for AS-Interface The addressing unit is used to each AS-Interface slave to assign an address to during commissioning. The device detects a connected slave module or a complete AS-i network and displays the found module in the LCD display. Via the on/down keys can each address can be individually set.
© Siemens AG 2011 AS-Interface System components and accessories Addressing units ■ Selection and ordering data 3RK1 904-2AB02 Version Order No. AS-Interface addressing unit V 3.0 • For AS-Interface modules and sensors and actuators with integrated AS-Interface in accordance with AS-i Specification V3.
© Siemens AG 2011 AS-Interface System components and accessories Analyzer ■ Overview ■ Benefits • Simple and user-friendly operation enables diagnostics of AS-Interface networks without help from specialists • Speedy troubleshooting thanks to intuitive display in statistics mode • Test logs provide verification of the state and quality of the installation for service and approval • Recorded logs facilitate remote diagnostics by technical assistance • Comprehensive trigger functions enable exact analysis
© Siemens AG 2011 AS-Interface System components and accessories Analyzer ■ Application (continued) Data mode Trace mode The presentation of message frames in the style of a classic field bus analyzer is indispensable for complex troubleshooting. Extensive trigger functions and recording and viewing filters are available for this purpose. An external trigger input and trigger output round off the scope of functions in order to find even the most difficult errors.
© Siemens AG 2011 AS-Interface System components and accessories Analyzer ■ Selection and ordering data Version Order No.
© Siemens AG 2011 AS-Interface System components and accessories Miscellaneous accessories ■ Selection and ordering data Version Order No. AS-Interface system manual Technical information and overview of the AS-Interface product range from Siemens, scope: approx.
© Siemens AG 2011 AS-Interface System components and accessories Miscellaneous accessories ■ Selection and ordering data (continued) Version Order No.
© Siemens AG 2011 AS-Interface System components and accessories Miscellaneous accessories ■ Selection and ordering data (continued) Version Order No. Control cables, assembled at one end Angular M12 socket for screw fixing, 4-pole, 4 x 0.34 mm2 A-coded, black PUR sheath, max. 4 A • Cable length 5 m 3RK1 902-4GB50-4AA0 3RK1 902-4GB50-4AA0 Angular M12 socket for screw fixing, 4-pole screw terminals, max. 0.75 mm2, A-coded, max.
© Siemens AG 2011 AS-Interface Software AS-Interface Function Block Library for SIMATIC PCS 7 ■ Overview The library contains modules for accessing the I/O data of AS-i slaves, modules for diagnostics of the AS-i system, and a faceplate for the PCS 7 Maintenance Station. The AS-i CP 343-2 / CP 343-2P masters are supported within an ET 200M station connected through PROFIBUS. For direct connection to PROFIBUS it is possible to use DP/AS-i Link Advanced as an AS-i single master and double master.
© Siemens AG 2011 AS-Interface Notes 6 6/150 Siemens IK PI · 2012