Specifications

Advanced parameters and commands
Pearleye Technical Manual V2.0.0
43
Advanced parameters and commands
This chapter is to illuminate the advanced configuration of the Pearleye P-007
LWIR / Pearleye P-030 LWIR models. For the control of an ex-factory set up
camera the intervention within the parameters stated here or rather the use of
the mentioned commands is only necessary in exceptional cases.
Two-point correction (A, B, E, J, K, N)
The configuration of the two-point correction comprises the following parame-
ters:
The parameter E controls the operation mode of the two-point correction. The
following value assignments are valid:
Parameter Description
A File number of the first correction image recorded at cold
reference temperature.
B File number of the first correction image recorded at warm
reference temperature.
E Two-point correction operating mode
J Set value of the correction image of the actually chosen
correction data set recorded at cold reference temperature.
K Set value of the correction image of the actually chosen
correction data set recorded at warm reference temperature.
N File number for the set values of all correction data sets.
Table 16: Advanced parameters: two-point correction
Value Description
0 Deactivated
Data is passed through transparently.
1 Activated
Correction data A and B with the set values J and K of the
actual correction memory page S is used.
2 Deactivated
Test mode: Correction data A are output as image data. (*)
Table 17: Parameter E: values