Instruction manual
Configuration of the camera
MARLIN Technical Manual
Page 104
11.4.7 Sequence control
It is possible to make certain settings for a sequence of images beforehand by using this register.
Offset Name Field Bit Description
0xF1000220 SEQUENCE_CTRL Presence_Inq [0] Indicates presence
of this feature
(read only)
--- [1..4]
AutoRewind [5]
ON_OFF [6] Enable/Disable this
feature
--- [7..15]
MaxLength [16..23] Max. possible
length of a
sequence (read
only)
SeqLength [24..31] Length of the
sequence
0xF1000224 SEQUENCE_PARAM --- [0..4]
ApplyParameters [5] Apply settings to
selected image of
sequence; auto-
reset
IncImageNo [6] Increment ImageNo
after
ApplyParameters
has finished
--- [7..23]
ImageNo [24..31] Number of image
within a sequence
Table 68: Sequence control register