Instruction manual

Prosilica GX Technical Manual V2.2.0
46
Camera interfaces
Lens control port
The lens control connector is a Hirose 3260-8S3. This connector provides the
signals necessary to control the iris, focus, and zoom of most commercially
available TV Zoom and Video-type auto-iris lenses. The cable side connector is
Hirose 3240-8P. The camera can be configured to operate lenses with unipolar
voltage requirements of 6–12 V or lenses that operate with bipolar voltages
from ±6 V up to ±12 V. This voltage level can be controlled through software. The
default voltage is set to 6 V. The current capacity for each axis is 50 mA.
Pin Signal Direction Description
1 Iris + Out Open Iris
2 Iris - Out Close iris
3 Focus + Out Focus far
4 Focus - Out Focus close
5 Zoom + Out Zoom out
6 Zoom - Out Zoom in
7 Video Iris Out PWM Signal for Iris Control
8 External GND --- External Ground for all lens control signals
Table 15: Prosilica GX lens connector definition
Caution
Do not exceed the lens manufacturers voltage specification.
Note
This cable side Hirose connector can be purchased from Allied
Vision.
P/N: 02-7004A
1
876
5
4
32