Instruction manual
Guppy PRO Technical ManualV4.1.0
123
Controlling image capture
Short exposure time:
If the following condition is true:
T
exp eff.
 = T
exp
 - T
frame
 < 0
you don’t get an IntEna signal and triggering is not possible.
Guppy PRO F-503, Trigger_Mode_0, global reset release 
shutter
• IntEna is high, when all pixels are integrated simultaneously.
• Readout starts with end of exposure of first row.
• Readout ends with (end of exposure of last row) + (1x T
row
).
 Figure 65: Trigger_Mode_0: Guppy PRO F-503 electronic rolling shutter (short exposure time)
Note
For activating global reset release shutter in an advanced reg-
ister see table 153.
 Figure 66: Trigger_Mode_0: Guppy PRO F-503: global reset release shutter
IntEna
T
exp
T
frame
No overlapping,
no IntEna,
 no flash
T
exp
 – T
frame
 < 0
FVal
IntEna
FVal
T
row
T
exp
Overlapping
good for
flash
T
exp