Camera interfaces
Camera I/O connector external circuit example
The trigger circuit is connected to a Texas Instruments SN74ACT244PWR buffer/
driver inside the camera.
Figure 31: Prosilica GE external circuit
Caution
Input: Incoming trigger must be able to source 10 μA.
Output: Sync output current is 24 mA.
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
1211
TRIGGER INPUT
OUT 2
OUT 3
HIROSE HR10A-10P-12P
CABLE SIDE
IN 1 (5 V TTL DRIVER)
OUT 2 (5 V TTL RECEIVER)