Camera attribute highlights
Camera attribute highlights
AVT cameras support a number of standard and extended features. The table
below identifies a selection of interesting capabilities of the Prosilica GE camera
family.
www
A complete listing of camera controls, including control defini-
tions can be found online:
PvAPI users: AVT GigE Camera and Driver Attributes document
VIMBA users: AVT GigE Camera and Driver Features document
Control Description
Gain control Manual and auto
Exposure control Manual and auto
White balance Red and blue channel; manual and auto control
External trigger event Rising edge, falling edge, any edge, level high, level
low
External trigger delay 0 to 60* s; 1 μs increments
Fixed rate control 0.001 fps to maximum frame rate
Imaging modes Free-running, external trigger, fixed rate, software
trigger
Sync out modes Trigger ready, trigger input, exposing, readout,
imaging, strobe, GPO
Region of interest Independent x and y control with 1 pixel resolution
Multicast Streaming to multiple computers
Event channel In-camera events including exposure start and trig-
ger are asynchronously broadcasted to the host com-
puter
Chunk data Captured images are bundled with attribute informa-
tion such as exposure and gain value
*May vary depending on the camera model