Specifications

Camera interfaces
Bigeye Technical Manual V2.0.0
36
Frame-sync output (Pin 15)
Bigeye P-132 The frame-sync output is only active in continuous operation.
The frame-sync output (active low) supplies approx. 1200 mV at a termination
with 75 .
Bigeye P-629 The frame-sync output becomes active at the beginning of an image output.
The frame-sync-output (active low) supplies approx. 900 mV at a termination
with 75 .
Bigeye P-1100 The frame-sync output is only active in continuous operation.
The frame-sync-output (active low) supplies approx. 1200 mV at a termination
with 75 .
Figure 19: Frame-sync output (Bigeye P-132)
Figure 20: Frame-sync output (Bigeye P-629)
Figure 21: Line-sync output (Bigeye P-1100)