Specifications
Advanced parameters and commands
Pearleye Technical Manual V2.3.0
48
Example
Activate the two-point correction
>E=1[CR]
The parameters A and B define both files out of which the reference images 
for the two-point correction data are loaded. The reference images in the file 
system are stored each in a closed sequence of file numbers. The loading pro-
cess following the camera start begins at the first cold reference image A . Then 
it is continued with the accompanying warm reference image B. In the follow-
ing step it is attempted to load the file numbers A+1, then B+1 and so on. 
This process is continued as long as one file within the sequence is missing in 
the flash or the maximum number of correction sets (actually 32) has been 
achieved.
If during operation the value of A or B is newly adjusted, this change causes 
the immediate data load out of this file. Different to the automatic loading pro-
cedure following the switch-on of the camera, the data are exclusively copied 
within the memory page S (see Chapter Select a correction data set (S) on 
 Figure 13: Schematic process of two-point correction
Load process
Cold reference image
A
Cold reference set value
J
Correction
data
0x ??????
...
...
Correction
data
0x ??????
0
0
n
n
Warm reference image
B
Warm reference set value
K
Correction
data
0x ??????
...
...
Correction
data
0x ??????
0
0
n
n