Technical information
 GigE Camera and Drivers Features V3.0.0
59
GigE IR & scientific camera and driver features
This document is a master document for all Allied Vision GigE camera models and is NOT camera specific    
GigE IR & scientific camera and driver 
features
Goldeye G and Goldeye G Cool are short-wave infrared GigE cameras that pro-
vides comprehensive and advanced set of features for infrared imaging require-
ments. This chapter describes the standard and advanced camera controls, as 
seen from the Vimba Viewer, for Goldeye G and Goldeye G Cool cameras using 
the GenICam standard feature naming convention. 
AcquisitionControl
This group of controls relates to image acquisition.
AcquisitionAbort [Command]
Software command to stop camera from receiving frame triggers and abort the 
current acquisition. A partially transferred image will be completed.
AcquisitionFrameCount [Integer] R/W
Defines the number of frames to capture in a limited sequence of images. Used 
with AcquisitionMode = MultiFrame and Recorder. In Recorder 
mode, AcquisitionFrameCount cannot exceed StreamHoldCapac-
ity.
AcquisitionFrameRate [Float] R/W
When TriggerSelector = FrameStart and either TriggerMode = 
Off or TriggerSource = FixedRate, this control specifies the frame 
rate. Depending on the exposure duration, the camera may not achieve the 
frame rate set here.
AcquisitionFrameRateLimit [Float] R
The maximum frame rate possible for the current exposure duration and image 
format.
Range:[1–65535] Default: 1 Unit: Frames
Range: [Camera dependent] Unit: Frames per second
Range: [Camera dependent] Unit: Frames per second