Installation manual

TurboStack Hubs with Management
35
If you are installing a coaxial cable segment without a BNC-T connector at
the end (as shown in Figure 32), you must enable the termination of the
port by turning the 50 termination switch ON (1).
Port Status Indicators
The port status indicators on the AT-TS08 hubs’ front panels provide
visual diagnostic and activity information for network analysis. The
indicators are either an individual port LED or a central indicator for box
level monitoring.
AT-TS08
Port Indicators
Each 10BASE2 port supports the following indicator functions with two
single-color front panel LEDs per port, shown in Figure 33 below:
ON LINE (Steady Green)— Indicates that the port is not partitioned.
RECEIVE (Flashing Amber)— Indicates that the port is receiving
Ethernet packets.
Figure 31: BNC-T at End of
10BASE2 Segment
Figure 32: BNC Connector at
End of Segment with
Internal Termination