User manual
Overview
12
Settings
Thin Ethernet Transformer . Each channel has a transformer IC
component that is only for thin Ethernet operation. This component must
be moved to a spare socket if thin Ethernet is not used. The placement of
these transformers is given below in Table 3
Configuring Channel 1 Note: Channel 1 is set at the factory to operate with Ethernet or IEEE
803.2 10BASE5.
Setting Channel 1 for Thin Ethernet Operation:
1. Remove any transformer in position T4A.
2. Install the transformer into position T4.
Setting Channel 1 for Ethernet or IEEE 802.310BASE5 Operation:
(Channel 2 Factory Setting)
Figure 14: Location of Headers
and Transformers
Network Type Channel 1 Channel 2
Ethernet T4A (Thick) T2A (Thick)
IEEE 802.3 10BASE5 T4A (Thick) T2A (Thick)
Thin Ethernet T4 (Thin) T2 (Thin)
Table 3: Thin Ethernet Transformers