Specifications

AT-TS08 Connectivity
34
Normal Cascade Port 8 is a dual-purpose port and has the label “NORMAL/CASCADE.
You can use it in the following ways:
To connect a network device, as you would any of the other ports
To extend the network to another hub via a link segment. If you use
Port 8 as a cascade port, you may connect the other end of the link
segment to Port 1 or any other standard 10BASE2 port, as shown
in Figure 30.
10BASE2 Wiring Specifications
10BASE2 (or thinnet) requires a thin coaxial cable, RG58. RG58 is a 10
MHz, baseband cable connected with BNC-series connectors. The cable
must be terminated with 50 terminators and grounded at one end.
Maximum segment length is 185 meters (606 ft.).
The thinnet coaxial cable is plugged directly into the BNC receptacle for
Ports 1 through 8 located on the front panel. Next to each of these ports is
the 50 termination switch (see Figure 30). If you are installing a BNC-T
connector (like the one shown in Figure 31) in the middle portion of a
segment, you must disable the ports’ termination by turning the switch
OFF (0).
Figure 30: AT-TS08 Cascade
connection
Port 8
Port 1
Termination
switch (1 of 8)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com