Specifications

TurboStack Hubs with Management
23
To remove a 10BASE2, 10BASE-T or fiber Optic (10BASE-FL)
appliqué
1. Snap off the plastic cover plate on the installed 10BASE2, 10BASE-T,
or 10BASE-FL appliqué. (See Figure 11 on page 17.)
2. Remove the two M3x6 flat-head appliqué screws (shown in Figure 19)
and pull out the appliqué.
3. Remove the 4-40 pan-head screws from the AUI connector and ribbon
cable assembly (reverse of Step 3 and related Figure 18 above).
4. Store the removed 10BASE2, 10BASE-T, or 10BASE-FL appliqué
assembly in a secure container for future use.
To install an AUI appliqué
1. Using the supplied screws, lock washers, and nuts, attach the AUI
appliqué connector plate and locking bracket (slide-kit) to the AUI
connector. (See Figure 14 on page 20.)
2. Using the two M3x6 flat-head appliqué screws, attach the AUI
appliqué to the hub faceplate. (See Figure 13 on page 20.)
3. Snap the AT-TSA5 (AUI) plastic cover plate in place on the hub
faceplate. (See Figure 11 on page 17.)
Back-panel
Features
All TurboStack hubs with management capability have the same back
panel layout and features, shown in Figure 20.
Firmware cassette port used to install new network management
software. (For more information, refer toTurboStack™ AT-S10
Firmware Module for TurboStack Hubs Operations Manual)
Interrepeater bus connector that attaches the TurboStack module
to the backplane bus in a concentrator chassis
Status indicators providing information on the hub as a whole. For
convenience, these LEDs appear on both the front and back panels.
Figure 20: TurboStack Hub
Back Panel
Firmware
cassette port
bus port
Interrepeater
Hub status LEDs