Hardware Reference 79
C613-03058-00 REV A
Figure38: Pin wiring diagram for a V.35 DTE transition cable to an AMPLIMITE 50-
way connector.
D50 SCSI-2 Male
(to router)
M34 Male
(to DCE)
Cable Shield
Insulating
Sheath
A Shield
B SIG G
P SDA (103)
SSDB
Y TCA (114)
AA TCB
R RDA (104)
TRDB
V RCA (115)
XRCB
C RTS (105)
D CTS (106)
F DCD (109)
H DTR (108)
E DSR (107)
L LL (141)
N RL (140)
Connect to backshell
1
→ TD 12
37
(−5V) 25
← TC 10
35
← RD 2
27
← RC 8
33
→ RTS 14
← CTS 3
← CD 5
→ DTR 13
← DSR 4
→ LL 16
→ RL 15
FGND 46
FSELB 47
Pin 26 Pin 50
Pin 1 Pin 25
D50 SCSI-2 Male — Pin View
Pin B
Pin D
Pin A
Pin C
M34 Male — Pin View
Ferrite
Cable
A
B
B
B
Network A
180R
180R
105R
200R
200R
Network B
300R
300R
Pin NN
Pin LL
Pin MM
Pin KK
Notes:
(1) → Output from router; ← Input to router.
(2) Use shielded cable with twisted pairs,
e.g. UL2919 28AWG. Twisted pairing
must be 1-26, 2-27, 3-28, etc.
(3) M34 connector shells must be metal.
Connect braid to connector shells to
make a 360° connection.
(4) Standard cable length is
2.05m ± 0.05m.
(5) Ferrite must be fitted to cable no more
than 25mm from rear of D50 SCSI-2
backshell.
(6) Resistors are 1% tolerance.
(7) See accompanying text for information
about earth loop conditions.
(8) Cable version 2.0.
A50V35T