Specifications

Table Of Contents
VP500 Communication Unit 51
17
mgcpConfiguration Parameters
The MGCP Configuration parameters allow you to set information
exclusive to VP500 communication units that run the Media Gateway
Control Protocol (MGCP).
Introduction The MGCP MIB is used with VP500 communication units that run the
Media Gateway Control Protocol (MGCP).
X To use the MGCP MIB
In the general Provisioning MIB, locate the
signalingProtocolsSwitch variable under the
signalingProtocolsGroup.
This variable allows you to switch from one protocol to
another.
Set the signalingProtocolsSwitch variable to 0=MGCP.
Reboot the VP500 communication unit.
After the VP500 communication unit restarts, it will use the
MGCP MIB.
General Parameter The following parameter allows you to set the UDP port number.
Table 54: MGCP MIB Version Parameter
Name Access Description Dynamic
mgcpMibVersion R-O MIB version. N/A
Table 55: General Parameter
Name Access Description Dynamic
mgcpConfigurationResidentialGatewayPort
Number
R/W MGCP Residential Gateway UDP port number. This is the UDP
port number on which the unit is listening for any MGCP request.
Default Value: 2427
No