Specifications

Chapter 8 - Unit Manager Configuration Administration Manual (SIP/MGCP Version)
AT-VP504E FXS 62
DHCP vs. Static
Configuration
Unit Manager information such as its IP address and port number can
be assigned through a DHCP server or set statically.
To use DHCP-assigned information:
1. Locate the
apaManagerUseDhcp
variable (under
apaManagerGroup
).
This variable defines whether the AT-VP504E FXS must get
its Unit Manager configuration through a DHCP server or not.
2. Set the
apaManagerUseDhcp
variable to 1=DHCP.
You can query the Unit Manager’s IP address and Port
number assigned by the DHCP server in the
apaManager
DhcpPrimHost
and
apaManagerDhcpPrimTrapPort
read-
only variables.
3. Set the DHCP Vendor Specific code of the Unit Manager in
the
apaManagerDhcpVendorSpecificCode
variable.
This code can be any number between 0 and 254. The
default value is 200.
To use static information:
1. Locate the
apaManagerUseDhcp
variable (under
apaManagerGroup
).
This variable defines whether the AT-VP504E FXS must get
its Unit Manager configuration through a DHCP server or not.
2. Set the
apaManagerUseDhcp
variable to 0=Static.
3. Set the following variables:
Table 28: Unit Manager Static Address
Variable Description
apaManagerStaticPrimHost Static Unit Manager IP address or
domain name.
Default Value: 192.168.0.10
apaManagerStaticPrimTrapPort Static Unit Manager IP port number.
Default Value: 162