Specifications

Chapter 2 - Installation Administration Manual (SIP/MGCP Version)
AT-VP504E FXS 24
6. When the AT-VP504E FXS has finished its provisioning
sequence, set the
interfaceUseDhcp
variable to 1, then turn
it off, plug it on the network, and turn it on again.
Factory Set-
tings Mode
This procedure allows to revert back to the default factory settings of
the AT-VP504E FXS. It deletes the MIB database of the unit and
creates a new configuration file with the default factory values. It should
be performed with the AT-VP504E FXS connected to a network with
access to a DHCP server. If the unit cannot find a DHCP server, it will
use the static address 192.168.0.1. In this case, your PC must use the
static IP address 192.168.0.10.
To use the
Default Settings
switch in Factory Settings mode:
1. Power the AT-VP504E FXS off.
2. Insert a small paper clip into the
Default Settings
switch hole
of the AT-VP504E FXS. While pressing the
Default Settings
switch, power the unit on.
The electrical outlet shall be installed near the AT-VP504E
FXS so that it is easily accessible. You must keep pressing
the paper clip for at least 15 seconds. Do not depress before
the three LEDs stop blinking and are steadily ON.
3. Release the paper clip.
The AT-VP504E FXS restarts.
This procedure resets all variables in the MIB modules to
their default value; defaults include the
interfaceUseDhcp
variable set to 1.
When the AT-VP504E FXS has finished its provisioning
sequence, it is ready to be used with a DHCP-provided IP
address and MIB parameters.
Note: The recovery mode does not alter any persistent configuration
data of the AT-VP504E FXS, except the
interfaceUseDhcp
variable.
Note: The factory default settings mode does alter any persistent
configuration data of the AT-VP504E FXS. The MAC address is re-
written with its own value.