Specifications

Getting Started — The Basics
20
Enter the letter I for IP parameters to access the following submenu:
Choose those parameters you want to change by simply entering
A for IP
address, B for subnet mask, C for gateway address or D through G for
manager addresses.
The first time you apply power to your network, you will find that the default
IP address is blank. This simply means that you must insert the initial IP
address manually.
A minimal configuration requires only an IP address and Subnet mask.
NOTE
In an ATM network environment, ensure that the Omega management
workstation is connected to a port with the same ELAN as the management
network port: either Port 9 for the AT-TS95TR or Port 17 for the AT-4016TR
and AT-4016F. If it is not the same, you will lose contact with the switch via
Telnet.
If you lose contact, either Telnet in from a station on the management port’s
ELAN, or initiate an Omega local session and reassign the management
station’s port to be on the same ELAN as the network port. ELANs are