AT-BSTACK1 Stacking Module For the AT-8324SX Fast Ethernet Switch Quick Install Guide PN 613-50114-00 Rev A
Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Electrical Safety and Emission Statement Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Viktig: Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser , åpner du til Tillegg A for å finne den oversatte sikkerhetsinformasjonen på ønsket språk. Importante: O Anexo A contém advertências de segurança traduzidas para instalar este equipamento. Quando vir o símbolo , leia a advertência de segurança traduzida no seu idioma no Anexo A. Importante: El Apéndice A contiene mensajes de seguridad traducidos para la instalación de este equipo.
Table of Contents Electrical Safety and Emission Statement ..............................................iii Table of Contents ........................................................................................... v Welcome to Allied Telesyn ......................................................................... vii Where to Find Web-based Guides.................................................................... vii Document Conventions...............................................................
Welcome to Allied Telesyn This guide contains instructions on how to install the AT-BSTACK1 Stacking Module in an AT-8324SX Fast Ethernet Switch. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation and technical information for all of our products. All web-based documents relating to this product and other Allied Telesyn products can be downloaded from the web site in pdf format.
Contacting Allied Telesyn There are several ways that you can contact Allied Telesyn technical support: online, telephone, fax, and e-mail. Online Support You can request technical support online by filling out the Tech-Assistant Form at www.alliedtelesyn.com/forms/feedtech.htm.
AT-BSTACK1 Quick Install Guide Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
For Sales or Corporate Information Allied Telesyn International, Corp. 19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191 Allied Telesyn International, Corp.
Overview The AT-BSTACK1 Stacking Module is designed for the AT-8324SX Fast Ethernet Switch. You use the module to create stacks of up to four switches. Running at a bandwidth of over 4 Gbps, this module provides a common interface to the attached switches, allowing the stack to function and be managed as a single device. Caution The stacking module is designed for the AT-8324SX Fast Ethernet Switch only. Do not install this module in any other Allied Telesyn device.
Installing the AT-BSTACK1 Stacking Module The following sections contain instructions on how to install the module. Verifying the Package Contents Check to be sure that your package contains the following items. If any of the items are missing or damaged, contact your Allied Telesyn representative.
AT-BSTACK1 Quick Install Guide Caution Air vents: The air vents must not be blocked on the unit and must have free access to the room ambient air for cooling. 9 Caution Operating Temperature: This product is designed for a maximum ambient temperature of 50°C. 10 Caution All Countries: Install this product in accordance with local and National Electric Codes. 11 Handling the Module Caution The AT-8324SX Stacking Module can be easily damaged by electrostatic discharge.
Installing the Module To install the module, perform the following procedure: 1. Power off the switch by disconnecting the AC power cord from the switch. If the switch is connected to a redundant power unit (RPU), disconnect the DC cable connection to the switch. Caution The switch must be powered off before installing or replacing the module. Installing the module with the switch powered on can damage the module. 2.
AT-BSTACK1 Quick Install Guide 3. Insert the AT-BSTACK1 module into the expansion slot, as shown in Figure 2. Holding the new module with the text on the front panel upright, carefully slide the module into the switch slot, ensuring that the edge connector is fully engaged. Once the module is installed, check to be sure that the front panel of the module is flush against the switch. Figure 2 Installing the Module 4. Secure the new module in place with the attached screws. 5.
Figure 3 Cabling the Switches 6. Power on the switch by reconnecting the previously removed power sources to the switch. The module port LEDs on the front-panel of the switches should indicate their status. The Status LED should be On, indicating the presence of the AT-BSTACK1 module. Refer to the AT-8324SX Fast Ethernet Switch Installation Guide for a description of all the system LEDs. If the stack is not functioning properly, see "Troubleshooting" below.
AT-BSTACK1 Quick Install Guide Troubleshooting If you experience any problems with the module, check the following items before contacting Allied Telesyn Technical Support: Ensure that all the switches in the stack are powered up. Ensure that the devices attached to the stack are powered up and operating correctly. Ensure that the stack modules are properly seated in their slots. Check the connectors on both ends of the stack cable to be sure they are properly engaged.
Technical Specifications Lists the technical specifications of the module. Table 1 Technical Specifications Physical Specifications Ports Two 68-pin SCSI connectors Cable Type SCSI Type 4 Size 12.25 x 90.70 x 2.74 cm (4.82 x 3.57 x 1.08 in.) Environmental Specifications Operating Temperature 0° C to 50° C (32° to 122° F) Storage Temperature -20° C to 70° C (-4° to 158° F) Operating Humidity 5% to 95% non-condensing Power Specifications Maximum Power Consumption 2 watts Standards IEEE 802.
Appendix A Translated Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-BSTACK1 Quick Install Guide 9 CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling. 10 OPERATING TEMPERATURE: This product is designed for a maximum ambient temperature of 50° degrees C. 11 ALL COUNTRIES: Install product in accordance with local and National Electrical Codes. Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
Standarder: Dette produkt tilfredsstiller de følgende standarder. 1 Radiofrekvens forstyrrelsesemission 2 ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger. 3 Immunitet EN55022 Klasse A IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
AT-BSTACK1 Quick Install Guide Eisen: Dit product voldoet aan de volgende eisen. 1 RFI Emissie 2 WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. 3 Immuniteit EN55022 Klasse A IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
Normes: ce produit est conforme aux normes de suivantes: 1 Emission d’interférences radioélectriquesEN55022 Classe A 2 MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates. 3 Immunité IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
AT-BSTACK1 Quick Install Guide Standardit: Tämä tuote on seuraavien standardien mukainen. 1 Radioaaltojen häirintä 2 VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. 3 Kestävyys EN55022 Luokka A IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
Standard: Questo prodotto è conforme ai seguenti standard. 1 Emissione RFI (interferenza di radiofrequenza) EN55022 Classe A 2 AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti. 3 Immunità IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
AT-BSTACK1 Quick Install Guide Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. 1 RFI stråling 2 ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. 3 Immunitet EN55022 Klasse A IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
Padrões: Este produto atende aos seguintes padrões. 1 Emissão de interferência de radiofrequênciaEN55022 Classe A 2 AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas. 3 Imunidade IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
AT-BSTACK1 Quick Install Guide Estándares: Este producto cumple con los siguientes estándares. 1 Emisión RFI 2 ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. 3 Inmunidad EN55022 Clase IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
Standarder: Denna produkt uppfyller följande standarder. 1 Radiostörning 2 VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. 3 Immunitet EN55022 Klass A IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
Appendix B Technical Support Fax Order Name _________________________________________________________________ Company ______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone ______________________________ Fax_______________________________ Incident Summary Model number of Allied
Appendix C AT-BSTACK1 Module Quick Install Guide Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.