Installation guide

AT-8216FXL, AT-8224XL, and AT-8288XL Installation Guide
47
Network Cabling Problems
If you have 10/100Base-TX (Fast Ethernet), some network problems may
be related to exceeding cabling distances. Refer to the standard IEEE
802.3u, Clause 29.3.1.2 on
Worst Case Path Delay Value
. This
document specifies that the collision domain diameter must be within
the following limits:
#
Under 100 meters (328 feet) for TX cabling
#
Under 412 meters (1,331.56 feet) for half-duplex FX cabling