Fast Ethernet Switches ® AT-8216FXL/MT AT-8216FXL/VF AT-8216FXL/SC AT-8224XL AT-D8224XL AT-8288XL/MT AT-8288XL/SC ! Installation Guide PN 613-10811-00 Rev C
Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale, CA 94085 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. CentreCom is a registered trademark of Allied Telesyn International, Corp. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Electrical Safety and Emission Statement Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Preface ......................................................................................................................................................................................................................7 Purpose of This Guide ...........................................................................................................................................................................................7 How This Guide is Organized ..............................
Table of Contents Chapter 2 Installation ...........................................................................................................................................................................................................29 Verifying the Package Contents ..................................................................................................................................................................... 30 Reviewing Safety Precautions ...................................
Preface Purpose of This Guide This guide is intended for network administrators who are responsible for installing and maintaining AT-8216FXL, AT-8224XL, AT-D8224XL, and AT-8288XL Series Fast Ethernet Switches. How This Guide is Organized This guide consists of the following chapters and appendices: Chapter 1, Hardware Description, describes the features and functions of the switches and the expansion modules. The chapter also describes several network topologies that use the fast Ethernet switches.
Preface Document Conventions This guide uses several conventions that you should become familiar with first before you begin to install the product: Note A note provides additional information. Warning A warning indicates that performing or omitting a specific action may result in bodily injury. Caution A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Where to Find Related Guides The Allied Telesyn web site at www.alliedtelesyn.com/support/ prd_libs.htm provides you with an easy way to obtain the most up-todate documentation for all of our products. All web-based documents relating to this product and other Allied Telesyn products can be downloaded from the web site in PDF format. There are several manuals that you will need in order to manage your Fast Ethernet switch.
Preface Contacting Allied Telesyn Technical Support There are several ways that you can contact Allied Telesyn technical support: online, telephone, fax, and e-mail. Online Support Telephone and Fax Support E-mail Support You can request technical support online by filling out the Online Technical Support Form at www.alliedtelesyn.com/forms/support.htm.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense. To obtain an RMA number, contact Allied Telesyn’s Technical Support at one of the following locations: North America 2205 Ringwood Ave.
Preface FTP Server If you need a driver for an Allied Telesyn device and you know the name of the driver, you can download the software by connecting directly to our FTP server at ftp://gateway.centre.com. At login, enter “anonymous”. Enter your e-mail address for the password as requested by the server at login.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide For Sales or Corporate Information Allied Telesyn International, Corp. 19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191 Allied Telesyn International, Corp.
Preface Tell Us What You Think If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the Send us Feedback Form at www.alliedtelesyn.com/forms/feedback.htm.
Chapter 1 Hardware Description The AT-8216FXL, AT-8224XL, and AT-8288XL Series Fast Ethernet Switches offer the following features: # Ethernet, Fast Ethernet, and Gigabit Ethernet connectivity # A small 1.
Hardware Description Switch Models Table 1 lists the switch models. Table 1 Switch Models Model1 Number of Ports Type of Port Type of Connector Maximum Distance AT-8216FXL/MT 16 100Base-FX MT-RJ 2 kilometers2 (1.25 miles) AT-8216FXL/VF 16 100Base-FX VF-45 2 kilometers2 (1.25 miles) AT-8216FXL/SC 16 100Base-FX SC 2 kilometers2 (1.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Figure 1 shows an example of a front panel of an AT-8216FXL Series Fast Ethernet Switch. This switch features 16 fiber optic ports with either SC, MT-RJ, or VF-45 connectors, depending on the model.
Hardware Description Hardware Features The switches have the following common hardware features: # Half- or full-duplex operation on all switched ports delivering up to 200 Mbps of bandwidth to servers, routers, or other switches # Auto-negotiation on all 10Base-T/100Base-TX ports for speed and duplex in compliance with IEEE 802.3u specifications (AT-8224XL and AT-8288XL switches only) # Non-blocking, clear-channel architecture delivers wire-speed switching and up to 8.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Network Management Features The following lists the switches’ network management features.
Hardware Description Physical Description The switches have the following front panel components: # Ethernet 100Base-FX ports (16 ports on an AT-8216FXL switch and eight ports on an AT-8288XL switch) # Ethernet 10Base-T/100Base-TX ports (24 ports on an AT-8224XL switch and eight ports on an AT-8288XL switch) # RS232 (DB9-F) connector for out-of-band management # Reset button # System and port status LEDs # Two expansion slots for optional 10/100Base-TX, 100Base-FX, 1000Base-SX, 1000Base-LX, and 1000Base-T
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Fault LED Expansion Module Slots Reset Button LED Color Function Key 10BASE-T / 100BASE-TX FAST ETHERNET SWITCH A 10BASE-T / 100BASE-TX 1X 3X 5X 7X 9X 11X PORT ACTIVITY 13X 17X 15X 19X 21X 23X L /A 100M LINK / D/C FULL DUP 1 3 5 ACTIVITY 7 9 11 13 RS-232 TERMINAL PORT 10M LINK / ACTIVITY HALF DUP/ COL 15 17 19 21 STATUS 23 FAULT L /A D/C B RPS L /A PWR D/C 2 2X 4X 6X 8X 10X 12X 14X 18X 16
Hardware Description Figure 7 shows the switch’s back panel with the AC connector. Figure 7 Back Panel Note The AT-D8224XL switch has a DC power terminal block on the back panel. Port LEDs Each switch port has two LEDs that indicate the following: # L/A LED - indicates a valid physical link with a device with packets being received/transmitted and speed of transmission # D/C LED - indicates half- or full-duplex and collisions Figure 8 shows the LEDs on the AT-8224XL switch.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide RS232 Connector Reset Button System LEDs The RS232, DB-9 female connector on the front panel of the switch is used to establish an out-of-band local management session with the switch and the AT-S24 management session. Establishing a local session requires a terminal or a personal computer with a terminal emulator program. The terminal is connected to the RS-232 port with a straightthrough cable. This button resets the switch.
Hardware Description Expansion Module Slots The two expansion slots on the front panel of the switch can accommodate a wide range of optional 10/100Base-TX, 100Base-FX, 1000Base-SX, 1000Base-LX, and 1000Base-T expansion modules. You can use the modules to interconnect distant network devices, build a high-speed backbone network, or attach additional nodes to the switch.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Network Topologies The following sections contain two examples of network configurations that use the switch models described in this guide. Standalone Configuration Figure 9 shows the AT-8224XL used as a standalone switch for a group of heavy traffic users. Switching on the desktop is either through a single end-station per switch port or through a multi-port hub.
Hardware Description Workgroup Configurations Figure 10 shows how the different switches can be incorporated into a large corporate network to form a Fast Ethernet infrastructure. A switch is located on each floor and servers are centralized in one room.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Where to Go Next Proceed to Chapter 2 for details on how to install the switch.
Chapter 2 Installation This chapter contains the following installation procedures: # Verifying the Package Contents # Reviewing Safety Precautions # Selecting a Site for the Switch # Planning the Installation # Installing the Switch on a Desktop # Installing the Switch in a Rack # Installing an Expansion Module The chapter also contains information on the system and expansion module LEDs.
Installation Verifying the Package Contents Make sure the following hardware components are included in your switch package. If an item is missing or damaged, contact your Allied Telesyn sales representative.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Reviewing Safety Precautions Please review the following safety precautions before you begin to install the switch in your network. Refer to Appendix D for translated safety statements in your language. Laser Class 1 laser product. " 6 Laser Do not stare into the laser beam. " 7 Warning Electric Shock Hazard: To prevent electric shock, do not remove the cover. There are no user-serviceable parts inside.
Installation Selecting a Site for the Switch Be sure to observe the following requirements when choosing a site for your switch: # Make sure that the switch’s power is accessible and cables can be easily connected. # Cabling must be away from sources of electrical noise such as radios, transmitters, broadband amplifiers, power lines, electric motors, and fluorescent fixtures. # Air flow around the switch and through its vents on the side and rear must not be restricted.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Planning the Installation Table 2 contains the cabling specifications for the switches. Table 2 Switch Cabling Specifications Model Type of Cabling Maximum Distance AT-8216FXL AT-8288XL (100Base-FX ports) 50/125 micron multimode or 62.5/125 micron multimode Full-duplex: 2 kilometers (1.
Installation Installing the Switch on a Desktop The Ethernet switch can be installed in a standard 19-inch rack or on a table or desktop. To install the switch in a rack, go to the section ‘Installing the Switch in a Rack’ on page 36. To install the switch as a table or desktop, perform the following steps: 1. Remove all components from the shipping package and store the packaging material in a safe location. 2. Locate a level, secure surface for the switch. 3.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide As power is applied to the switch, the Fault LED (shown in Figure 12) flashes as the switch runs a series of internal self tests. After the switch has finished running its self tests, the Fault LED will stop flashing and will remain OFF. Refer to the section ‘Switch LEDs’ on page 41 for information on all of the system and port LEDs. RS-232 TERMINAL PORT STATUS OL Fault LED FAULT RPS PWR RESET Figure 12 Fault LED 5.
Installation Installing the Switch in a Rack To install the Ethernet switch in a standard 19-inch rack, perform the following steps: 1. Remove all components from the shipping package and store the packaging material in a safe location. 2. To prepare the switch, place it on a level, secure surface. 3. If you purchased an expansion module for the switch, install the module by following the instructions in the section ‘Installing an Expansion Module’ on page 38. 4.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Caution Air vents must not be blocked and must have free access to the room ambient air for cooling. " 13 6. Mount the switch in the rack using standard screws (not provided). 7. Apply AC power to the switch by plugging the power cord into the AC power connector on the back panel of the unit (shown in Figure 11) and plugging the other end into a power outlet. Warning The power cord is used as a disconnection device.
Installation Installing an Expansion Module This section contains instructions for installing an optional expansion module in the switch. An optional expansion module package should include the following items: # One expansion module # One quick install guide # Warranty card Note For information on cabling specifications for the expansion module, refer to the quick install guide shipped with the module. To install an expansion module, perform the following steps: 1.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide If you are installing only one expansion module in the switch, you should install the module in slot A (upper slot). While the module will work in slot B (bottom slot) with slot A empty, the port numbering assignments will change if you later install a module in slot A. This could affect the VLAN memberships on the switch and this could require you to adjust your VLAN configurations.
Installation Setting Up a Terminal for Local Management If you are installing the switch in a TCP/IP environment or if you intend to manage the switch from a remote site, you must first assign an IP address to the switch using the Omega management interface, which comes pre-installed on the switch along with the AT-S24 switch software. To start an Omega management session, perform the following steps: 1.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Switch LEDs Table 3 describes the system LEDs on the Ethernet switch. Table 3 Switch System LED Status LED State Description Fault Solid Red The switch or management software is malfunctioning. Flashing Red The switch is booting, running diagnostic tests, writing messages to FLASH, or transferring files using XMODEM. OFF Normal operation.
Installation Warranty Registration When you have finished installing the switch, you should register your product by completing the enclosed warranty card and sending it in, or by visiting our web site at www.alliedtelesyn.com/forms/warranty.htm and completing the on-line registration.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Where to Go Next Now that the switch is operational, you are ready to configure and monitor it as explained in the AT-S24 Management Software User’s Guide, which is available from Allied Telesyn’s web site at www.alliedtelesyn.com/support/prd_libs.htm.
Chapter 3 Troubleshooting This chapter provides information on how to detect and resolve problems with your switch.
Troubleshooting At the First Sign of a Problem Perform the following tasks when you first become aware of a problem with the switch: # Make sure the power cord is securely connected and the power voltage is not fluctuating. # Check the data cables for secure connections and make sure the device at the other end of a connection is operational. # Use Omega to read statistics and run diagnostics. For instructions, refer to the AT-S24 Management Software User’s Guide.
AT-8216FXL, AT-8224XL, and AT-8288XL Installation Guide Network Cabling Problems If you have 10/100Base-TX (Fast Ethernet), some network problems may be related to exceeding cabling distances. Refer to the standard IEEE 802.3u, Clause 29.3.1.2 on Worst Case Path Delay Value. This document specifies that the collision domain diameter must be within the following limits: # Under 100 meters (328 feet) for TX cabling # Under 412 meters (1,331.
Troubleshooting Calling Technical Support When contacting Allied Telesyn for support on any of its products, you will need to provide Technical Support with the following information: # Model and serial number # Software version number # Description of the problem Refer to Allied Telesyn’s web site at www.alliedtelesyn.com for a list of worldwide locations.
AT-8216FXL, AT-8224XL, and AT-8288XL Installation Guide How the Switch Reports Problems The switch detects and processes errors as follows: # The LEDs indicate problems with the ports and power. For information on the LEDs, refer to ‘Switch LEDs’ on page 41. # In a TCP/IP environment, if you have configured the software correctly, the management software triggers an SNMP trap message. As a result, the software then sends traps to alert the network manager when a trigger occurs.
Troubleshooting Common Problems This section lists common possible sources of errors and the actions required to correct them. Link /Activity LED on Any Port is OFF This can indicate: # A loose data cable. # The device at the other end of the connection is powered OFF. # The 10/100Base-TX data cable is not wired correctly (straight/ crossed) for the device. # The port’s selected transmission mode does not match that of the attached device.
AT-8216FXL, AT-8224XL, and AT-8288XL Installation Guide Perform the following steps in sequence; you need not proceed to the next step if the problem is resolved: 1. Secure the power cord to the power source and check the Power LED to see if it is ON. 2. Ensure that the voltage is within the required levels in your region. 3. If possible, logon to Omega and run Diagnostics if you can (Administration>Diagnostics ) and record any failures. 4. Contact Allied Telesyn’s Technical Support for assistance.
Appendix A Technical Specifications Table 5 lists the technical specifications for the AT-8216FXL, AT-8224XL, AT-D8224XL, and AT-8288XL switches. Table 5 Technical Specifications Physical Specifications Dimensions (H x W x D) 6.48 cm x 42.93 cm x 35.60 cm (2.55 in x 16.9 in x 14.0 in) Weight 5 kg (11 lbs) Required Ventilation on All Sides 19 cm (7.
Technical Specifications Table 5 Technical Specifications (Continued) Safety and Electromagnetic Emissions Certifications Safety: UL 1950 CSA 22.2 No. 950 EN 60950 (TUV) EMI: FCC Class A EN55022 Class A VCCI Class A Immunity: EN50082-1 Quality and Reliability: MTBF > 50,000 hrs MTTR < 1/2 hr DOA < 1% Table 6 shows the pin assignments for the switch’s RJ-45 connectors.
Appendix B Switch Default Settings This appendix lists the switch’s factory default software settings. Settings Default IP Address Subnet Mask 0.0.0.0 0.0.0.
Appendix C DC Terminal Block Wiring Instructions This appendix contains instructions on how to connect the AT-D8224XL switch to a DC power source. The instructions describe how to connect the DC terminal block on the rear panel of the LAN equipment to a 36 - 60 V DC power source. Reviewing Safety Precautions Please review the following safety precautions before you begin to connect the LAN equipment to a DC power source.
DC Terminal Block Wiring Instructions Connecting the LAN Equipment to a DC Power Supply To connect the equipment to a DC power source, perform the following instructions: Warning As a safety precaution, a 10 Amp circuit breaker should be installed at the supply end of the cable to be used with this LAN equipment. ALWAYS connect the wiring to the LAN equipment first before connecting the wiring to the breaker. To avoid the danger of physical injury from electrical shock, do not work with HOT feeds.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide 3. Connect the frame ground wire to the terminal marked with the ground symbol by inserting the wire into the terminal and tightening the connection with a flathead screwdriver. Warning When installing this equipment, always ensure that the frame ground connection is installed first and disconnected last. " 6 4. Connect the positive feed to the terminal block marked + (plus). 5. Connect the negative feed to the terminal block marked - (minus).
Appendix D Translated Electrical Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Translated Electrical Safety and Emission Information Standards: This product meets the following safety standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide " 12 PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible. " 13 CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling. " 14 OPERATING TEMPERATURE: This product is designed for a maximum ambient temperature of 40° degrees C. " 15 ALL COUNTRIES: Install product in accordance with local and National Electrical Codes.
Translated Electrical Safety and Emission Information "8 ACHTUNG: GEFÄHRLICHE SPANNUNG Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile. Das Gerät steht unter Hochspannung und darf nur von qualifiziertem technischem Personal geöffnet werden. Vor Anschluß der LAN-Kabel, Gerät vom Netz trennen. "9 GEFAHR DURCH BLITZSCHLAG GEFAHR: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters ausführen. " 10 VORSICHT: DAS NETZKABEL DIENT ZUM TRENNEN DER STROMVERSORGUNG.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide " 22 Warnung: “Sicherheitsrisiko” Prüfen Sie, daß aus dem installierten Draht keine freiliegenden Kupferlitzen herausragen. Bei korrekter Installation sollten aus dem Anschlußklemmblock keine freiliegenden Kupferlitzen vorstehen. Freiliegende Kabel führen genug Spannung, um Personen zu gefährden, die diese Drähte berühren. " 23 Hinweis: Dieses System kann mit positiv geerdeten oder negativ geerdeten Gleichstromsystemen betrieben werden.
Translated Electrical Safety and Emission Information " 17 Bemærk: Hvis switchen forbindes til jævnstrømsnet skal den føres med skinnekabel, der skal være UL mærket type TC normeret til 600 V, 908C, med tre ledere af mindst tykkelse 14 AWG (amerikansk ledningsmål). " 18 Advarsel: INSTALLERING OG UDSKIFTNING AF DETTE UDSTYR BØR KUN UDFØRES AF AUT. EL-INSTALLATØR. " 19 Advarsel: Der bør indskydes en 10 A automatsikring på forsyningsenden af kablet til dette LAN-udstyr.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide " 11 ELEKTRISCHE TOESTELLEN VAN KLASSE 1 DIT TOESTEL MOET GEAARD WORDEN. De stekker moet aangesloten zijn op een juist geaarde contactdoos. Een onjuist geaarde contactdoos kan de metalen onderdelen waarmee de gebruiker eventueel in aanraking komt onder gevaarlijke spanning stellen. " 12 AAN TE SLUITEN APPARATUUR, de contactdoos wordt in de nabijheid van de apparatuur geïnstalleerd en is gemakkelijk te bereiken.
Translated Electrical Safety and Emission Information Normes: ce produit est conforme aux normes de suivantes: "1 Emission d’interférences radioélectriques "2 MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide " 19 Avertissement: Par mesure de sécurité, un disjoncteur de 10 A doit être installé au point d’alimentation électrique du câble devant être utilisé avec cet équipement de réseau local (LAN). Connectez TOUJOURS le câblage à l’équipement LAN avant de le connecter au disjoncteur. Pour éviter tout risque de blessure corporelle par électrocution, ne travaillez pas lorsque le matériel est sous tension.
Translated Electrical Safety and Emission Information " 12 PISTORASIAAN KYTKETTÄVÄ LAITE; pistorasia on asennettava laitteen lähelle ja siihen on oltava esteetön pääsy." " 13 HUOMAUTUS: Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi. " 14 KÄYTTÖLÄMPÖTILA: Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 40°C. " 15 KAIKKI MAAT: Asenna tuote paikallisten ja kansallisten sähköturvallisuusmääräysten mukaisesti.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide "6 AVVERTENZA Prodotto laser di Classe 1. "7 AVERTENZA Non fissare il raggio con gli occhi. "8 AVVERTENZE ELETTRICHE ATTENZIONE: PERICOLO DI SCOSSE ELETTRICHE Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili dall’utente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un tecnico specializzato e qualificato.
Translated Electrical Safety and Emission Information " 21 Avvertenza: Quando si installa questo apparecchio, accertarsi sempre che il collegamento a massa del telaio sia sempre il primo ad essere effettuato e l’ultimo ad essere scollegato. " 22 Avvertenza: "Pericolo!" Controllare che il filo installato non abbia trefoli in rame esposti. Se l’installazione è stata effettuata in modo corretto, non vi deve protrudere dalla morsettiere alcun trefolo in rame esposto.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide " 17 Merknad: En kanalkabel er nødvendig for å kople til strømkilden hvis enheten drives av strøm fra et likestrømsnett. Kanalkabelen må være utstyrt med UL-merke med type TC, normert for 600 V og 90 ºC med tre ledere som har en tykkelse på minst 14 AWG (amerikansk ledningsmål). " 18 Advarsel: DETTE UTSTYRET SKAL BARE MONTERES ELLER SKIFTES UT AV KVALIFISERT PERSONELL SOM HAR GJENNOMGÅTT OPPLÆRING.
Translated Electrical Safety and Emission Information " 10 CUIDADO: O CABO DE ALIMENTAÇÃO É UTILIZADO COMO UM DISPOSITIVO DE DESCONEXÃO. PARA DESELETRIFICAR O EQUIPAMENTO, desconecte o cabo de ALIMENTAÇÃO. " 11 ELÉTRICO - EQUIPAMENTOS DO TIPO CLASSE 1 DEVE SER FEITA LIGAÇÃO DE FIO TERRA PARA ESTE EQUIPAMENTO. O plugue de alimentação deve ser conectado a uma tomada com adequada ligação de fio terra. Tomadas sem adequada ligação de fio terra podem transmitir voltagens perigosas a peças metálicas expostas.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide Estándares: Este producto cumple con los siguientes estándares. "1 Emisión RFI "2 ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. "3 Inmunidad EN50082-1 1997 "4 Seguridad eléctrica EN60950, UL 1950, CSA 950 "5 Laser EN60825 EN55022 Clase A SEGURIDAD "6 ¡ADVERTENCIA! Producto láser Clase 1.
Translated Electrical Safety and Emission Information " 18 Advertencia: ÚNICAMENTE EMPLEADOS CAPACITADOS Y COMPETENTES TIENEN LA AUTORIZACIÓN DE INSTALAR O REPONER DICHO EQUIPO. " 19 Advertencia: Por razones de precaución, se debe instalar un cortacircuitos de 10 amperios en el extremo de alimentación del cable que se utilizará con este equipo LAN. SIEMPRE conecte los cables al equipo LAN primero, antes de conectarlos al cortacircuitos.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Installation Guide " 11 ELEKTRISKT - TYP KLASS 1 UTRUSTNING DENNA UTRUSTNING MÅSTE VARA JORDAD. Nätkabeln måste vara ansluten till ett ordentligt jordat uttag. Ett felaktigt uttag kan göra att närliggande metalldelar utsätts för högspänning. Apparaten skall anslutas till jordat uttag, när den ansluts till ett nätverk. " 12 UTRUSTNING MED PLUGG. Uttaget skall installeras i utrustningens närhet och vara lättåtkomligt".
Index A AC connector, 23 ACTIVITY/LINK LED, 41 architecture clear-channel, 18 auto-negotiation, 18 B BootP, 18 C cabling requirements, 33, 47 clear-channel architecture, 18 configuration, 25 conventions, document, 8 D DC terminal block, 22, 57 desktop installation, switch, 34 DHCP support, 18 diagnostics, running, 51 distances, cabling, 33, 47 duplex mode full-, 18 half-, 18 DUPLEX/COLLISION LED, 41 E expansion modules, 20, 38 F Fault LED, 41, 51 flash memory, 18 full-duplex, 18 I IEEE 802.
Index P physical description, 20 port LEDs, 22 power failure, 50 problems, troubleshooting, 46 Protocol, Spanning Tree, 19 publications, list of, 9 PWR LED, 41, 50 R rack installation, 36 remote connection, Telnet, 51 RESET button, 23, 46, 51 resetting through software, 51 RJ-45 pin assignments, 54 RPS LED, 41 RS232 connector, 23 S safety precautions, 31 SNMP Management Information Base, 19 SNMP traps from switch, TCP/IP, 49 software resetting the switch, 51 Spanning Tree Protocol, 19 specifications, techn