Specifications

Operations Manual
105
Bridge Age Time: ST AGE_TIME [1] = 20 ([Bridge number] =
value)
ST AGE_TIME [2] = 20
:
:
ST AGE TIME [64] = 20
Allowable configuration data: A numeric value ranging from 6 - 40
Default Value: 20
Bridge Hello Time: ST HELLO TIME [1] = 2 ([Bridge number] =
value)
ST HELLO TIME [2] = 2
:
:
ST HELLO TIME [64] = 2
Allowable configuration data: A numeric value
ranging from 0 - 10
Default Value: 2
Bridge Forwarding Delay: ST FWD DELAY [1] = 15 ([Bridge number] =
value)
ST FWD DELAY [2] = 15
:
:
ST FWD DELAY [64] = 15
Allowable configuration data: A numeric value ranging from 4 - 30
Default Value: 15
Bridge ATM State: ST ATM STATE [1] = DISABLED ([Bridge
number] = value)
ST ATM STATE [2] = DISABLED
:
:
ST ATM ADMIN STATE [64] = DISABLED
Allowable configuration data: DISABLED, ENABLED
Default Value: DISABLED