Specifications
TurboStack Series Hubs
39
The AT-TS24TRS repeats 10BASE-T signals according to IEEE 802.3 hub
specifications. In an eight-slot department concentrator, up to 181 ports
may be monitored (seven Slaves containing 24 10BASE-T station ports
each and one Master containing 12 10BASE-T station ports and one AUI
network port).
Note
The AUI network ports on multiple AT-TS24TRS or AT-TR24TS hubs in an
eight-slot department concentrator cannot be used because they reside on
the back panel of the hub and are blocked by the backplane.
You can expand the number of ports by stacking multiple AT-TS24TRS
hubs through the backplane connector, making a single logical hub.
Controllers The AT-TS24TRS hub uses an ATI proprietary multiple port hub
controller to retime and regenerate signals and communicate with the
network management software. The port status for each of the ports is
indicated by an LED display.
AT-TS24TRS Port Configurations
Network Port The AUI port on the AT-TS24TRS resides on the back panel and is used to
connect the hub to the network only in a standalone configuration. In a
managed hub, the Master’s AUI port may be used for the network
connection. In a non-managed hub configuration, if you are using a two- or
three-slot chassis, one AUI port is used for the network connection and the
remaining AUI port(s) can be used for station connections.
Different media connections can be accommodated through the use of an
ATI micro transceiver. For a list of the ATI micro transceivers available for
network connections, see Table 3 on page 19 of this manual.
Station Ports The AT-TS24TRS hub is factory built with 24 RJ45 connectors.
UTP Hub-to-MAU Wiring
For a 10BASE-T link between a hub and a Media Access Unit (MAU)
transceiver or Network Interface Controller (NIC), the cable is wired
straight-through. That is, an RJ45 receptacle at the hub would wire pin-
to-pin to the RJ45 receptacle at the MAU. The AT-TS24TRS follows IEEE’s
10BASE-T hub standard for an embedded crossover function. Each port is
an MDI-X interface with the receive and transmit pairs crossed internally.
Note
For information on UTP cabling, refer to the 10BASE-T section in
Appendix A.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com