Specifications
TurboStack Series Hubs
15
Attention
Improper installation may expose the repeaters to debris and block vents,
causing damage because of insufficient cooling. When installing multiple ATI
hubs in a chassis with power, setting the chassis voltage switch too high (at
240V when 120V is required) will cause overheating of the fans. Setting the
voltage too low (at 120V when 240V is required) will reduce the effectiveness
of the fans and thus cause overheating of the installed repeater modules.
Check the specific chassis model to determine the correct voltage setting.
Attention
You should always quit the Omega management program at the end of
each session. Otherwise, you might encounter such problems as not being
able to exchange management hubs in a chassis.
Attention
If a fault light and/or the port activity (link) LEDs on the Master illuminate
when you first power-up a hub in a chassis, there may be a problem with
the unit. The recommended sequence of corrective steps is as follows: a)
turn off the power and power-up a second time; b) insert a firmware
cassette in the back panel of the unit; c) initiate a Return Material
Authorization (RMA) to ATI.
Note
If you need to reinstall or update the network management software in a
hub module, refer to the TurboStack™ AT-S10 Firmware Module for
TurboStack Hubs Operations Manual.
The following procedure details how to install a TurboStack Slave module in
a chassis. This procedure is based on the assumption that another module
with management capability is already functioning in the chassis as the
Master unit.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com