Specifications

Overview
10
Note
Depending on the model used, the AUI network port on some Slave
modules cannot be used in a seven-slot department concentrator because
they reside on the back panel of the repeater and are blocked by the
backplane.
Module
Functions
In the department concentrator configuration, the modules perform
different functions:
The top module becomes the Master. It downloads software to and
serves as the reporting unit for other units in the concentrator. It
also controls the management functions.
The module in the slot directly below the Master becomes the
Backup. It assumes management functions if the Master is
removed.
Note
In a department concentrator configuration, both the Master and the
Backup modules must have management capability.
All hub modules between the Master or Backup and the AT-TS90TR
or AT-TS95TR switch in the bottom chassis slot function as Slaves.
They report management information to the Master but do not
perform any control functions.
The bottom slot of the 7-slot chassis may be occupied by either an
AT-TS90TR switch or an AT-TS95TR switch.
Note
The bottom slot of the 7-slot chassis may be left empty with no effect on the
operation of the individual Master, Backup, or Slave modules mounted in
the top six chassis slots. With no switch installed, however, there is no
communication among the units.
Note
Chassis equipped with fans have variable voltage settings—either 120V or
240V. When installing multiple ATI hubs in a chassis with power, setting
the chassis voltage switch too high (at 240V when 120V is required) will
cause overheating of the fans. Setting the voltage too low (at 120V when
240V is required) will reduce the effectiveness of the fans and thus cause
overheating of the installed repeater modules. Check the specific chassis
model to determine the correct voltage setting.
A variety of department concentrator chassis models is available for
TurboStack products. These include chassis with standard or segmented
backplanes. These chassis address a range of needs for different sized
networks and uses. Call your ATI sales representative for details.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com