Log and Trap Listing by Reason Code Overview
3-49
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
Explanation A routine audit has discovered a discrepancy between the data run-
ning in RAM and the data stored in the system database. On a duplex
system, if the failure is on the inactive CFC only, then the system
automatically restarts the inactive CFC to cause a resync to fix
the problem. Whether a simplex or duplex system, if the failure is
on the active CFC then manual action is required, and any configu-
ration changes made by users are not saved to the system database.
Action Perform the following:
1. Restart the CFC
2. If necessary, go to the last known backup.
Alarms The following components are affected:
Component Status Alarm
CFC12 Degraded Minor
CFC200 Degraded Minor
CFC200 Failed Minor
CFC24 Degraded Minor
CFC24 Failed Minor
CFC4 Degraded Minor
CFC6 Degraded Minor
CFC6 Failed Minor
Note: For an active CFC, the status is Degraded, since there is no backup CFC.
2.31.2 Database Transaction Failure
Message Database Transaction Failure
Severity Major
Explanation While this alarm is present any persistent configuration data that
is entered may not be stored in the persistent database. (CAUTION:
While this alarm is present any persistent configuration data that
is entered may not be stored in the persistent database.)
Action Perform the following:
1. All management logs, error, and crash logs should be collected and the database
restored (RESTORE DATABASE)
2. Recover with a database restoration using the RESTORE DATABASE command.
3. Contact Allied Telesis Support.
Alarms The following components are affected: