User guide

Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
3-46
GE Port Degraded Minor
IP Interface Degraded Minor
SHDSL Port Degraded Minor
XE Port Degraded Minor
2.27.3 Classifier Resources Exceeded
Message Port Degradation Set
Severity Minor
Explanation The reported card/port has exceeded the maximum resources available
for classifier configuration. CLASSIFIER and/or ACCESSLIST func-
tionality may not behave correctly.
Action Perform the following:
1. Verify classifier provisioning.
2. Disable and enable the port.
3. Disable and enable the card.
4. If the problem still exists, contact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
ADSL Port Degraded Minor
FE Port Degraded Info
FX Port Degraded Minor
GE Port Degraded Minor
IP Interface Degraded Minor
SHDSL Port Degraded Minor
XE Port Degraded Minor
2.28 RMON001 - risingAlarm
2.28.1 Not Applicable
Message Rising Alarm. Index:
Severity Minor
Explanation A rising alarm is generated when a Remote Monitoring (RMON) statis-
tic crosses over a user provisioned threshold over a specified
period of time. The message contains the index of the ethernet
interface affected, the specific statistic involved, the type of