User guide
Log and Trap Listing by Reason Code Overview
3-45
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
1. Verify classifier provisioning.
2. Disable and enable the port.
3. Disable and enable the card.
4. If the problem still exists, contact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
• ADSL Port Degraded Info
• FE Port Degraded Minor
• FX Port Degraded Minor
• GE Port Degraded Minor
• IP Interface Degraded Minor
• MLPPP Degraded Minor
• SHDSL Port Degraded Minor
• XE Port Degraded Minor
2.27.2 Classifier Configuration Not Supported
Message Port Degradation Set
Severity Minor
Explanation The reported card/port is not capable of supporting the provisioned
classifier configuration. This may be due to the reported card run-
ning an older software revision. CLASSIFIER and/or ACCESSLIST func-
tionality may not behave correctly.
Action Perform the following:
1. Verify software release running in the associated card.
2. Verify classifier provisioning.
3. Disable and enable the port.
4. Disable and enable the card.
5. If the problem still exists, contact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
• ADSL Port Degraded Minor
• FE Port Degraded Info
• FX Port Degraded Minor