User guide

Log and Trap Listing by Reason Code Overview
3-45
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
1. Verify classifier provisioning.
2. Disable and enable the port.
3. Disable and enable the card.
4. If the problem still exists, contact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
ADSL Port Degraded Info
FE Port Degraded Minor
FX Port Degraded Minor
GE Port Degraded Minor
IP Interface Degraded Minor
MLPPP Degraded Minor
SHDSL Port Degraded Minor
XE Port Degraded Minor
2.27.2 Classifier Configuration Not Supported
Message Port Degradation Set
Severity Minor
Explanation The reported card/port is not capable of supporting the provisioned
classifier configuration. This may be due to the reported card run-
ning an older software revision. CLASSIFIER and/or ACCESSLIST func-
tionality may not behave correctly.
Action Perform the following:
1. Verify software release running in the associated card.
2. Verify classifier provisioning.
3. Disable and enable the port.
4. Disable and enable the card.
5. If the problem still exists, contact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
ADSL Port Degraded Minor
FE Port Degraded Info
FX Port Degraded Minor