User guide

Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
3-42
2. Verify far-end equipment.
3. Disable/enable port.
Alarms The following components are affected:
Component Status Alarm
ADSL Port Failed Info
DS1 Port Failed Major
E1 Port Failed Major
EPON Port Failed Major
GE Port Failed Major
SHDSL Port Failed Info
XE Port Failed Major
2.26.9 Loss of Sync (LOSY)
Message Port Fault Set
Severity Major
Explanation The port has lost the sync source from the far end equipment.
Action Perform the following:
1. Verify sync source.
2. Verify far-end equipment.
3. Disable/enable port.
Alarms The following components are affected:
Component Status Alarm
GE Port Failed Major
XE Port Failed Major
2.26.10 Remote BFD Session Failed
Message Port Fault Set
Severity Info
Explanation For Bi-Directional Forwarding Detection (BFD), produced when the
remote interface is reporting that its BFD State is down. The con-
nection may be lost even though there is no link (LOS) failure.
Action Perform the following:
1. Check the wiring/connections with the remote interface.
Alarms The following components are affected: