Log and Trap Listing by Reason Code Overview
3-35
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
Alarms The following components are affected:
Component Status Alarm
• ATMBOND Degraded Info
• MLPPP Degraded Minor
• ONU Degraded Info
• PPP Degraded Minor
2.22.3 Classifier Resources Exceeded
Message Interface Degradation Set
Severity Info
Explanation The reported interface has exceeded the maximum resources available
for classifier configuration. CLASSIFIER and/or ACCESSLIST func-
tionality may not behave correctly.
Action Perform the following:
1. Verify classifier provisioning.
2. Disable and enable the interface.
3. Disable and enable the card.
4. If the problem still exists, contact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
• ATMBOND Degraded Info
• MLPPP Degraded Minor
• ONU Degraded Info
• PPP Degraded Minor
2.23 IPIF001 - (To Be Supplied)
2.23.1 IP Interface Configuration Failed
Message To Be Supplied
Severity Info
Explanation IP interface configuration failed. This alarm is more likely on the
INBAND interface than the MGMT interface, since more configuration
is required (CFC and line card for INBAND, as opposed to just CFC
for MGMT). Note that internal classifiers are used on the line
cards hosting the inband VLANs for traffic extraction to the CFC.