User guide

Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
3-30
Component Status Alarm
None
2.12 IGMP001 - mcChannelLimitPerShelfExceeded
2.12.1 Not Applicable
Message Maximum Allowed Layer 2 MC Group limit reached
Severity Major
Explanation The number of concurrent multicast groups on the system has been
reached. An IGMP Report is being dropped due to reaching the sys-
tem's limit.
Action Perform the following:
1. No action is required.
Alarms The following components are affected:
Component Status Alarm
None
2.13 IGMP002 - mcHighWaterMarkPerCardCleared
2.13.1 Not Applicable
Message MC count at High Threshold mark cleared
Severity Info
Explanation The IGMP group limit per card has dropped below the high water
mark.
Action Perform the following:
No action is required.
Alarms The following components are affected:
Component Status Alarm
None
2.14 IGMP003 - mcGroupLimitPerMACExceeded
2.14.1 Not Applicable
Message MAC Addr <n> on slot <n> port <n> VID <n> tried to join <n> which
would be more than 5 MC groups!