Log and Trap Listing by Reason Code Overview
3-27
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
2.9 CHAS001 - entConfigChangeTrap
2.9.1 Not Applicable
Message Chassis Configuration Change
Severity Warning
Explanation A card in the chassis has been created or deleted.
Action Perform the following:
1. No action is required.
Alarms The following components are affected:
Component Status Alarm
None
2.10 FAN001 - atnFanFaultRaised
2.10.1 Fan Module Not Present
Message Fan Module Not Present
Severity Critical
Explanation The fan module is not present in the shelf.
Action Perform the following:
1. To B e S u p p l i e d
Alarms The following components are affected:
Component Status Alarm
FM4 Not Installed Major
FM8 Not Installed Major
2.10.2 Fans Not Rotating Properly
Message Fan Module Failure Raised
Severity Minor
Explanation One or more of the fans in the fan module is not functioning prop-
erly. The fan could be obstructed by a foreign object or the fan may
be faulty. If there are no obstructions then the fan module should
be replaced.
Action Perform the following: