Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
3-24
• GE Card Online Major
• GE24POE Online Major
• GE24SFP Online Major
• NTE8 Online Major
• POTS24 Card Online Minor
• SHDSL24 Online Minor
• XE4 Online Major
2.4.4 McastGroupLimit
Message Card Info Failure Raised
Severity Info
Explanation More IGMP Reports have been received on one Service Module than the
provisioned slot's group limit (GRPLIMIT).
Action Perform the following:
1. Verify traffic engineering for card.
2. Clear the alarm using CLEAR ALARMS command.
Alarms The following components are affected:
Component Status Alarm
• ADSL Online Info
• EPON2 Online Info
• FE10 Online Info
• FX10 Online Info
• GE Card Online Info
• GE Virtual Card Online Info
• GE2 Online Info
• NTE8 Online Info
• SHDSL24 Online Info
• XE Card Online Info
2.4.5 Out of Sync
Message Card Info Alarm Raised
Severity Info