Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
3-24
GE Card Online Major
GE24POE Online Major
GE24SFP Online Major
NTE8 Online Major
POTS24 Card Online Minor
SHDSL24 Online Minor
XE4 Online Major
2.4.4 McastGroupLimit
Message Card Info Failure Raised
Severity Info
Explanation More IGMP Reports have been received on one Service Module than the
provisioned slot's group limit (GRPLIMIT).
Action Perform the following:
1. Verify traffic engineering for card.
2. Clear the alarm using CLEAR ALARMS command.
Alarms The following components are affected:
Component Status Alarm
ADSL Online Info
EPON2 Online Info
FE10 Online Info
FX10 Online Info
GE Card Online Info
GE Virtual Card Online Info
GE2 Online Info
NTE8 Online Info
SHDSL24 Online Info
XE Card Online Info
2.4.5 Out of Sync
Message Card Info Alarm Raised
Severity Info