User guide
Log and Trap Listing by Reason Code Overview
3-23
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
2.4.2 File Corruption
Message Card Failure Raised
Severity Warning
Explanation A CRC calculation check has failed on one or more software load
files that are resident in the flash memory of the specified con-
trol module card.
Action Perform the following:
1. Verify FLASH file integrity using the AUDIT FILES command and remove any corrupted
files.
Alarms The following components are affected:
Component Status Alarm
• CFC12 Online Info
• CFC200 Online Info
• CFC24 Online Info
• CFC4 Online Info
• CFC6 Online Info
2.4.3 Inconsistent Load
Message Card Failure Raised
Severity Info
Explanation The card is running a software version that does not match the soft-
ware version running in the Control Module. As a result, some fea-
tures may not function as expected.
Action Perform the following:
1. The card needs to have its software version upgraded to match the Control Module.
Alarms The following components are affected:
Component Status Alarm
• ADSL Card Online Minor
• CES8 card Online Major
• EPON2 Online Major
• FE10 card Online Minor
• FX10 Card Online Minor
• GE Card Online Major