User guide
Log and Trap Listing by Reason Code Overview
3-21
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
1. Verify load file preference settings. Most likely the load file doesn’t match the card type.
Alarms The following components are affected:
Component Status Alarm
• ADSL Failed Minor
• CES8 Failed Major
• CFC200 Failed Major
• EPON2 Failed Major
• FE10 Failed Minor
• FX10 Failed Minor
• GE Card Failed Major
• GE24POE Failed Major
• GE24SFP Failed Major
• NTE8 Failed Major
• POTS24 Failed Minor
• SHDSL24 Failed Minor
• XE4 Failed Major
2.3.19 Unable to Access Card
Message Card Failure Raised
Severity Major
Explanation The control module failed to communicate with the specified card
during some maintenance activity. The problem could be due to high
traffic running through the card that exceeds it processing capac-
ity. The problem could also be with card seating, or the card may be
defective.
Action Perform the following:
1. If a CFC card, reseat the card. If this fails replace the card. If this fails, contact Allied
Telesis Technical Support.
2. If this is an SM card, disable the card, and enable the card. If the alarm is still not
cleared, Reseat the card. If the alarm is still not cleared, replace the card.
Alarms The following components are affected:
Component Status Alarm
• ADSL Failed Minor
• CES8 Failed Major