Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
3-20
2. For duplex systems, swap activity, then replace the faulty card.
3. If the problem is still not resolved, contact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
• CFC12 Degraded Minor
• CFC200 Degraded Minor
• CFC24 Degraded Minor
• CFC4 Degraded Minor
• CFC6 Degraded Minor
Note: For this alarm, it is possible to swap CFCs.
2.3.17 Simplex
Message Card Info Alarm Raised
Severity Minor
Explanation The inactive Control Module is not online, so the system is running
in simplex mode.
Action Perform the following:
1. If this is intentional, no action is required.
Alarms The following components are affected:
Component Status Alarm
• CFC200 N/A Major
• CFC24 Any Minor
• CFC6 Any Minor
Note: Since the CFC200 works in load sharing mode, going to simplex means traffic
could be affected.
2.3.18 Software Version Compatibility
Message Card Failure Raised
Severity Minor
Explanation The card's load preferences are set to a software load file whose
version is not compatible with the particular type and version of
card hardware.
Action Perform the following: