User guide

Log and Trap Listing by Reason Code Overview
3-19
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
1. Disable/enable the card.
2. Reseat the card if necessary.
3. Replace the card if necessary.
4. If the problem is still not resolved, contact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
ADSL Failed Minor
ARP Failed Minor
CES8 Failed Major
CFC200 Failed Major
CFC24 Failed Minor
CFC6 Failed Minor
EPON2 Failed Major
FE10 Failed Minor
FX10 Failed Minor
GE Card Failed Major
GE24POE Failed Major
GE24SFP Failed Major
NTE8 Failed Major
POTS24 Failed Minor
PPP Failed Minor
SHDSL24 Online Minor
XE Port Failed Major
XE4 Failed Major
Note: For the CFC200, this is for the inactive unit only.
2.3.16 RTC Battery
Message Card Failure Raised
Severity Major
Explanation The real time clock battery on the card is defective.
Action Perform the following:
1. For simplex systems, replace the CFC card.