User guide
Log and Trap Listing by Reason Code Overview
3-19
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
1. Disable/enable the card.
2. Reseat the card if necessary.
3. Replace the card if necessary.
4. If the problem is still not resolved, contact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
• ADSL Failed Minor
• ARP Failed Minor
• CES8 Failed Major
• CFC200 Failed Major
• CFC24 Failed Minor
• CFC6 Failed Minor
• EPON2 Failed Major
• FE10 Failed Minor
• FX10 Failed Minor
• GE Card Failed Major
• GE24POE Failed Major
• GE24SFP Failed Major
• NTE8 Failed Major
• POTS24 Failed Minor
• PPP Failed Minor
• SHDSL24 Online Minor
• XE Port Failed Major
• XE4 Failed Major
Note: For the CFC200, this is for the inactive unit only.
2.3.16 RTC Battery
Message Card Failure Raised
Severity Major
Explanation The real time clock battery on the card is defective.
Action Perform the following:
1. For simplex systems, replace the CFC card.