User guide

Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
3-14
Component Status Alarm
ADSL Failed Minor
CES8 Failed Major
CFC200 Failed Major
CFC24 Failed Minor
CFC6 Failed Minor
EPON2 Failed Major
FE10 Failed Minor
FX10 Failed Minor
GE Card Failed Major
GE Virtual Card Failed Minor
GE24POE Failed Major
GE24SFP Failed Major
NTE8 Failed Major
POTS24 Failed Minor
SHDSL24 Online Minor
XE Card Failed Major
XE4 Failed Major
2.3.10 Load Card Failed
Message Card Failure Raised
Severity Major
Explanation The system failed in an attempt to transfer a software load file
from the control module to the card's flash memory. The card may
have defective flash memory, or there could be a problem with the
load file itself.
Action Perform the following:
1. Verify load file existence using SHOW FILES, and fix if neces-
sary.
2. Verify load file integrity using AUDIT FILES, and fix if neces-
sary.
3. Disable/enable card again.
4. Disable card, load the card manually using PUT FILE, then enable
the card again.
5. Disable the card, reseat the card, enable it again.
6. Disable the card, replace the card, enable it again.