User guide
Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
3-14
Component Status Alarm
• ADSL Failed Minor
• CES8 Failed Major
• CFC200 Failed Major
• CFC24 Failed Minor
• CFC6 Failed Minor
• EPON2 Failed Major
• FE10 Failed Minor
• FX10 Failed Minor
• GE Card Failed Major
• GE Virtual Card Failed Minor
• GE24POE Failed Major
• GE24SFP Failed Major
• NTE8 Failed Major
• POTS24 Failed Minor
• SHDSL24 Online Minor
• XE Card Failed Major
• XE4 Failed Major
2.3.10 Load Card Failed
Message Card Failure Raised
Severity Major
Explanation The system failed in an attempt to transfer a software load file
from the control module to the card's flash memory. The card may
have defective flash memory, or there could be a problem with the
load file itself.
Action Perform the following:
1. Verify load file existence using SHOW FILES, and fix if neces-
sary.
2. Verify load file integrity using AUDIT FILES, and fix if neces-
sary.
3. Disable/enable card again.
4. Disable card, load the card manually using PUT FILE, then enable
the card again.
5. Disable the card, reseat the card, enable it again.
6. Disable the card, replace the card, enable it again.