User guide
Log and Trap Listing by Reason Code Overview
3-13
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
• ADSL Failed Minor
• CES8 Failed Major
• CFC200 Failed Major
• CFC24 Failed Minor
• CFC6 Failed Minor
• EPON2 Failed Major
• FE10 Failed Minor
• FE2 Failed Minor
• FX10 Failed Minor
• GE Card Failed Major
• GE Virtual Card Failed Major
• GE24POE Failed Major
• GE24SFP Failed Major
• NTE8 Failed Major
• POTS24 Failed Minor
• SHDSL24 Online Minor
• XE Card Failed Major
• XE4 Failed Major
2.3.9 Heartbeat Lost
Message Card Failure Raised
Severity Minor
Explanation The card failed a routine heartbeat check, where the control module
attempts to verify message communication with the card. The problem
could be due to high traffic running through the card that exceeds
it's processing and messaging capacity. The problem could also be
due to a software exception in the card.
Action Perform the following:
1. Disable the card and enable card.
2. Replace card if necessary. For simplex systems, replace the card.
3. For duplex systems, swap activity, then replace the faulty card.
4. If the problem is still not resolved, contact Allied Telesis Support.
Alarms The following components are affected: