User guide

Log and Trap Listing by Reason Code Overview
3-11
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
be a problem with provisioning associated with the card, or the
card may be defective.
Action Perform the following:
1. Verify the load file preference settings.
2. Verify the provisioning data.
3. Disable and enable the card again.
4. Disable the card, reseat the card, enable it again.
5. Disable the card, replace the card, enable it again.
Alarms The following components are affected:
Component Status Alarm
ADSL Failed Minor
CES8 Failed Major
CFC200 Failed Major
EPON2 Failed Major
FE10 Failed Minor
FE2 Failed Minor
FX10 Failed Minor
GE24POE Failed Major
GE24SFP Failed Major
NTE8 Failed Major
POTS24 Failed Minor
SHDSL24 Online Minor
XE Card Failed Major
XE4 Failed Major
2.3.7 Diags Failed
Message Card Info Alarm Raised
Severity Major
Explanation The card failed diagnostic testing. The card is probably defective.
Action Perform the following:
1. If the active CFC for duplex system, switch activity and replace the card during a low-
traffic period.
Alarms The following components are affected: