Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (Allied Telesis Product Logs with
Traps)
3-10
• ADSL Failed Minor
• CES8 Failed Major
• EPON2 Failed Major
• FE10 Failed Minor
• FX10 Failed Minor
• GE Card Failed Major
• GE24POE Failed Major
• GE24SFP Failed Major
• NTE8 Failed Major
• POTS24 Failed Minor
• SHDSL24 Online Minor
• XE4 Failed Major
2.3.5 Card Diags Failed
Message Card Failure Raised
Severity Major
Explanation The card failed diagnostic testing. The card is probably defective.
Action Perform the following:
1. Replace the card.
Alarms The following components are affected:
Component Status Alarm
• GE Card Failed Major
• GE Virtual Card Failed Major
• GE24POE Failed Major
• GE24SFP Failed Major
• XE Card Failed Major
• XE4 Failed Major
2.3.6 Config Failed
Message Card Failure Raised
Severity Major
Explanation The card failed to configure properly. The card could be running an
incorrect load that does not support the provisioning, there could