Log and Trap Listing by Reason Code Overview
2-19
Log Reference for SBx3100 and iMAP Series Switches (SBx3112 Logs with Traps)
2.7.6 PSU No Communication
Message PSU Failure Raised
Severity Major
Explanation A PoE PSU has been installed in one PoE PSU slot and a System PSU is
installed in the other PoE PSU slot. (A Hardware Not Recognized log
is also output.)
Action Perform the following:
1. Remove the System PSU from the POE (A or B) slot and place it in the correct slot (C
or D).
Alarms The following components are affected:
Component Status Alarm
• PSU Failed Major
2.7.7 PSU Output Voltage Fault
Message PSU Failure Raised
Severity Major
Explanation The POE PSU has been incorrectly placed in a SYS PSU slot (C or D).
Action Perform the following:
• Remove the PSU and place it in the correct POE (A or B) slot.
Alarms The following components are affected:
Component Status Alarm
• PSU Failed Major
2.8 SHLF001 - atnShelfFaultRaised
2.8.1 POE Usage Exceeds Power Threshold
Message To Be Supplied
Severity Info
Explanation The power thresholds that have been set have been exceeded.
Action Perform the following:
1. Add a PSU (if applicable) or remove PoE interfaces.
Alarms The following components are affected:
Component Status Alarm