User guide

Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (SBx3112 Logs with Traps)
2-10
2.1.12 PSE High Temp Detected
Message To Be Supplied
Severity Major
Explanation The GP24POE card has exceeded the temperature threshold. Service
could be affected.
Action Perform the following:
1. Check the card and replace the GE24POE card.
Alarms The following components are affected:
Component Status Alarm
GE24POE Degraded Major
2.1.13 PSE Power Failed
Message To Be Supplied
Severity Major
Explanation The GP24POE card no longer has power to supply the POE subscriber
lines.
Action Perform the following:
1. Replace the card.
Alarms The following components are affected:
Component Status Alarm
GE24POE N/A Major
2.1.14 SD Card Failed
Message Card Failure Raised
Severity Major
Explanation The SD card in the active CFC200 has failed, and so cannot written
in or copied out.
Action Perform the following:
1. Activate and deactivate the SD card.
2. Replace the SD card.
Alarms The following components are affected:
Component Status Alarm
CFC200 Online Major
CFC200 Online Major